Skip to main content
Siemens 5SU9346-1CN40 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SU9346-1CN40 RCBO, 40 A, 30 mA, Type AC, C-

MPN5SU9346-1CN40

Siemens SENTRON 5SU9346-1CN40, RCBO, 4-pole, 40 A, 30 mA, Type AC, C-curve, 6 kA per EN 60898, 440 V insulation voltage, IP20, 7 MW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SU9346-1CN40 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SU9346-1CN40 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9346-1CN40 — Mechanical
ParameterValue
Mounting positionany
Width in modular units7
Maximum75 °C
Minimum-40 °C
Width126 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9346-1CN40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9346-1CN40 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens SENTRON 5SU9346-1CN40 is a 4-pole RCBO — residual current operated circuit breaker with overcurrent protection — rated 40 A at 30 °C ambient, with a 30 mA residual trip threshold and a C tripping characteristic. This is the variant that combines the MCB and RCD functions in a single 7-module-width unit, saving a DIN-rail position compared to separate devices.

The insulation voltage is rated 440 V, matching standard 400 V three-phase networks with headroom. The 40 A rating holds at 30 °C; at 40 °C it derates to 37.2 A, at 45 °C to 35.6 A, at 50 °C to 34.8 A, and at 55 °C to 34 A (–) — so if the panel ambient runs hot, factor the derating into the load schedule. That is fine for general-purpose circuits feeding resistive, inductive, or conventional rectifier loads, but if the downstream equipment includes variable-speed drives, LED drivers, or UPS systems that generate DC fault components, a Type A or Type F RCD would be required.

The IP20 rating is standard for enclosed distribution boards — the touch protection is integral.

Frequently asked questions

What is the breaking capacity of 5SU9346-1CN40?

The rated short-circuit breaking capacity is 6 kA per EN 60898, suitable for most sub-distribution boards where the prospective fault current is below that level.

What is the difference between 5SU9346-1CN40 and 5SU9304-1KK32?

The 5SU9304-1KK32 is a 4-pole RCBO with a 40 A rating and 30 mA residual current, but with a B tripping characteristic instead of C. The B-curve trips at 3–5 times rated current, making it more suitable for resistive loads and long cable runs where nuisance tripping from inrush is not a concern. The C-curve on the 5SU9346-1CN40 handles moderate inrush from motor-starter and lighting circuits better. Both share the same 6 kA breaking capacity per EN 60898 and the same 7 MW footprint, so they are mechanically interchangeable in the panel — the choice is purely about the load's inrush profile.

Where can I buy 5SU9346-1CN40 and how is it quoted?

The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
5SU9346-1CN40