Siemens 5SY4313-6KK11 — 3-Pole MCB (DIN Rail)

Siemens 5SY4313-6KK11 SENTRON MCB, 3P, B-Curve, 10kA

MPN5SY4313-6KK11

Siemens SENTRON 5SY4313-6KK11 miniature circuit breaker, 3-pole, B tripping characteristic, 10 kA interrupting capacity per EN 60898-1, 20 kA per IEC 60947-2, 400 V AC, 3 MW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4313-6KK11 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY4313-6KK11 — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-220 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY4313-6KK11 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.7 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY4313-6KK11 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY4313-6KK11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

Rated 10 kA interrupting capacity per DIN EN60898-1 and 20 kA per IEC 60947-2 at 400 V AC, it handles fault currents common in 400 V three-phase industrial networks.

For a 400 V AC circuit, the 10 kA breaking capacity per EN 60898-1 covers the vast majority of industrial service-entrance and sub-distribution fault levels; the 20 kA rating per IEC 60947-2 applies when the breaker is certified to the higher industrial standard, giving a safety margin for high-fault installations like transformer secondaries or large motor control centers. DC rating: 60 V operating voltage, 72 V max, with 15 kA interrupting capacity per IEC 60947-2. That makes it usable on 48 V DC control buses or 60 V battery strings, but not for 110 V DC traction circuits. The 50/60 Hz AC rating is single-phase and multi-phase at 440 V max — covers 400 V line-to-line systems with headroom. Temperature derating is specified: max 95% RH at 55 °C, dropping to 35% RH at 75 °C. In a sealed, non-ventilated panel near a heat source, the upper ambient limit of 75 °C is the absolute ceiling — expect nuisance tripping above it. The -40 °C minimum covers cold storage or unheated shelters.

Integration & Compliance

The 54 mm width (3 MW) is standard for 3-pole MCBs; it shares the same footprint as other SENTRON 5SY-series breakers, so a panel laid out for a 5SY4304-7CV or 5SY4310-7CV accepts this unit without rewiring or rail repositioning. The product is explicitly designated for railway applications (EN 50155 environment) and mechanical engineering / industry duty. Sealable (padlockable) handle for lockout/tagout compliance. Rated IP20 with connected conductors — not for wet or dusty locations without an enclosure.

Frequently asked questions

What are the key ratings of the 5SY4313-6KK11?

3-pole, B-curve MCB rated 10 kA per EN 60898-1 and 20 kA per IEC 60947-2 at 400 V AC. DC rating is 60 V operating (72 V max) with 15 kA interrupting capacity. Frequency 50/60 Hz.

Will the 5SY4313-6KK11 drop into a panel specified for a 5SY4304-7CV?

Yes — same 3-pole, 3-MW footprint (54 mm wide). No rewiring or rail repositioning needed. The 5SY4313-6KK11 has a higher interrupting capacity (10 kA vs lower-rated siblings) and a B-curve, so verify the trip characteristic matches the load type.

How do I get pricing and availability for the 5SY4313-6KK11?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What compliance documentation does the 5SY4313-6KK11 carry?

Designed to DIN EN60898-1 and IEC 60947-2. Halogen-free and silicon-free. Rated for pollution degree 3 and overvoltage category III. Suitable for railway applications per the product designation.

MPN
5SY4313-6KK11