Skip to main content
Siemens 5SY4313-6 — 3-Pole MCB (DIN Rail)

Siemens 5SY4313-6 SENTRON MCB, 3P B-Curve 13 A, 10 kA

MPN5SY4313-6
Active

Siemens SENTRON 5SY4313-6 miniature circuit breaker, 3-pole, B-curve, 13 A rated, 10 kA (EN 60898) / 20 kA (IEC 60947-2), 3 MW, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4313-6 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY4313-6 — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-220 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY4313-6 — Electrical
ParameterValue
Rated current (AC)13 A
Rated voltage (AC, multi-phase)440 V
5SY4313-6 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
5SY4313-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

Siemens 5SY4313-6 — 3-pole B-curve MCB at 13 A

Rated breaking capacity hits 10 kA per EN 60898 and 20 kA per IEC 60947-2, with a DC rating of 15 kA per IEC 60947-2. That's enough headroom for most industrial panel secondary-side protection — the 20 kA IEC figure is what you'd use for coordination studies under 60947-2. For motor or transformer primary-side protection, you'd typically step up to a C-curve.

Fastening uses the quick assembly system, so it clips on and off without tools.

Thermal derating and environmental range

Rated 13 A at 35 °C ambient. Derates to 12.48 A at 40 °C, 12.22 A at 45 °C, 11.95 A at 50 °C, 11.67 A at 55 °C, and 11.39 A at 60 °C. If your panel internal ambient runs hot, factor that in — at 50 °C you lose about 1 A of headroom. Operating temperature range spans -40 °C to 75 °C, with humidity limits of 95% up to 55 °C, 55% up to 70 °C, and 35% at 75 °C.

Designed for mechanical engineering and industry applications per its suitability listing. Sealable — allows lockout/tagout provisions on the toggle. Combined top and bottom terminals simplify busbar and outgoing wiring. Energy limitation class 3 indicates it limits let-through energy effectively during a fault, reducing stress on downstream components. Touch protection is built in. The product designation per IEC 81346-2 and DIN EN 61346-2 is 'F' (protective device).

Current lifecycle stage — Siemens continues to manufacture this order code.

Frequently asked questions

What is the breaking capacity of 5SY4313-6?

10 kA per EN 60898, 20 kA per IEC 60947-2 at AC, and 15 kA per IEC 60947-2 at DC. The 20 kA IEC figure is the one to use for coordination studies under 60947-2.

How does 5SY4313-6 compare to 5SY4140-7?

The 5SY4140-7 is a higher-rated variant (40 A vs 13 A) in the same SENTRON B-curve 3-pole family. Physical footprint (3 MW, 54 mm width) and breaking capacities are identical. The 5SY4313-6 drops into the same DIN-rail panel position without rewiring — only the current rating changes.

Where can I buy 5SY4313-6 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the latest market position.

What compliance documentation does Siemens provide for 5SY4313-6?

The part is halogen-free and silicon-free, and carries the SENTRON brand with designations per IEC 81346-2 and DIN EN 61346-2. Standard Siemens MCB documentation (declaration of conformity, RoHS/REACH statements) is available upon request through the supply channel.

MPN
5SY4313-6