Siemens 5SY4363-6 SENTRON MCB, 3P, B-Curve, 10kA IEC

MPN5SY4363-6
Active

Siemens SENTRON 5SY4363-6, 3-pole miniature circuit breaker, B characteristic, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC, 60 V DC.

$63.50Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4363-6 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY4363-6 — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-215 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY4363-6 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)6 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY4363-6 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY4363-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

The breaker carries approvals to IEC / EN 60898-1, IEC / EN 60947-2, and UL 1077 / CSA C22.2 No. 235. That means it is accepted in European (CE-marked) and North American (UL/CSA) installations — a single SKU for multi-region panels. Energy limitation class 3 limits let-through energy, reducing downstream damage on a fault. No neutral conductor switching; this is a straight 3-pole device for line-side protection only.

Frequently asked questions

Where can I buy 5SY4363-6 and how do I get a price?

The part is available to quote on request. Submit an RFQ through this listing; availability and current pricing are confirmed at quote time. No stock count or price is displayed here.

Will 5SY4363-6 drop into a panel specified around 5SY4140-7 without rewiring?

No. The 5SY4140-7 is a different pole/current variant in the same SENTRON family, but the 5SY4363-6 is a 3-pole B-curve breaker with a specific interrupting capacity and terminal layout. It shares the same DIN-rail footprint (3 MW, 54 mm wide) but the electrical ratings differ — verify the branch circuit requirements before substituting.

What compliance documentation does Siemens provide for 5SY4363-6?

The breaker is certified to IEC / EN 60898-1, IEC / EN 60947-2, and UL 1077 / CSA C22.2 No. 235. It is halogen-free and silicon-free. Standard RoHS and REACH declarations are available from Siemens upon request.