Skip to main content
Siemens 5SY4406-6 — 4-Pole MCB (DIN Rail)

Siemens 5SY4406-6 SENTRON MCB, 4P, B-curve, 10 kA IEC, 35 kA

MPN5SY4406-6
Active

Siemens SENTRON 5SY4406-6, 4-pole miniature circuit breaker, tripping characteristic B, 10 kA (EN 60898) / 35 kA (IEC 60947-2) breaking capacity, 400 V AC, 72 mm width, 76 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4406-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4406-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SY4406-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY4406-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4406-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4406-6 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)2.1 W

Product details

What this 4-pole B-curve MCB delivers for your panel

The Siemens 5SY4406-6 is a 4-pole miniature circuit breaker from the SENTRON series, rated for 400 V AC and carrying a B tripping characteristic — meaning it trips between 3 and 5 times rated current, the standard choice for resistive and general-purpose loads where nuisance tripping from inrush is not expected. Breaking capacity is 10 kA per EN 60898-1 and 35 kA per IEC 60947-2, with a DC rating of 15 kA at 60 V (max 72 V) per IEC 60947-2, and 5 kA under UL 1077 / CSA C22.2 No.235 — so it covers both residential-style and industrial fault-current levels in the same footprint.

Standards and compliance — what the approvals mean for your install

The 5SY4406-6 is certified to IEC / EN 60898-1 (the residential and commercial MCB standard) and IEC / EN 60947-2 (the industrial breaker standard), plus UL 1077 and CSA C22.2 No.235 — so it is accepted in European, UK, and North American installations where supplementary protection is required. Halogen-free and silicon-free construction reduces the risk of corrosive gas emission under fault — relevant for sealed enclosures or environments sensitive to silicone outgassing.

Frequently asked questions

What compliance documentation does Siemens provide for 5SY4406-6?

The breaker is certified to IEC / EN 60898-1, IEC / EN 60947-2, UL 1077, and CSA C22.2 No.235, and is halogen-free and silicon-free.

Will 5SY4406-6 drop into a panel specified around 5SY4140-7 without rewiring?

Both are 4-pole SENTRON MCBs with the same 72 mm width and DIN-rail mounting, so the footprint is identical — no rewiring needed for the panel layout, but verify the tripping characteristic and breaking capacity match your coordination study.

MPN
5SY4406-6