Siemens 5SY4415-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY4415-7 SENTRON MCB, 4P, 1.6A, C-Curve, 10kA/35kA

MPN5SY4415-7
Active

Siemens SENTRON, miniature circuit breaker, 4-pole, 1.6 A, C characteristic, 10 kA (EN 60898) / 35 kA (IEC 60947-2), 4 MW, IP20, -40 to 75 °C.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4415-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4415-7 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC1.6 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY4415-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-235 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY4415-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4415-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

Siemens 5SY4415-7 SENTRON MCB — 4-pole, 1.6 A, C-curve, 10/35 kA

The Siemens 5SY4415-7 is a 4-pole miniature circuit breaker from the SENTRON series, rated 1.6 A at AC with a C tripping characteristic. It breaks fault currents up to 10 kA per EN 60898 and 35 kA per IEC 60947-2, giving you two SCCR ratings to work with depending on the standard your panel follows.

The 1.6 A rating is the continuous current at 35 °C; above that, you need to derate: 1.5 A at 45 °C, 1.47 A at 50 °C, 1.44 A at 55 °C, and 1.4 A at 60 °C. If your enclosure runs hot, factor that in. The 10 kA breaking capacity under EN 60898 covers most standard commercial/industrial distribution boards; the 35 kA rating under IEC 60947-2 gives you headroom for high-fault installations like main switchboards or near large transformers.

Frequently asked questions

How do I get current pricing and availability for 5SY4415-7?

We source the 5SY4415-7 to order against an RFQ. Submit a quote request and we'll confirm current pricing and availability at that time.

What is the breaking capacity of 5SY4415-7?

The 5SY4415-7 has a 10 kA breaking capacity per EN 60898 and a 35 kA breaking capacity per IEC 60947-2, giving you two SCCR ratings depending on the applicable standard.

What temperature range does 5SY4415-7 handle?

Operating temperature range is -40 °C to 75 °C. The rated current of 1.6 A applies at 35 °C; derate to 1.5 A at 45 °C, 1.47 A at 50 °C, 1.44 A at 55 °C, and 1.4 A at 60 °C.