Siemens 5SY4416-5 — 4-Pole MCB (DIN Rail)

5SY4416-5 SENTRON 4-Pole MCB, 16A, Type A, 10kA

MPN5SY4416-5
Active

Siemens SENTRON 5SY4416-5, miniature circuit breaker, 4-pole, 16 A, Type A, 400 V AC, 10 kA to EN 60898, 20 kA to IEC 60947-2.

$338.66Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4416-5 — Identification
ParameterValue
Type / order code5SY4
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4416-5 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated current (In), AC16 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY4416-5 — Protection
ParameterValue
Tripping characteristic (trip curve)A
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-220 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY4416-5 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY4416-5 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4416-5 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The 5SY4416-5 is a SENTRON 4-pole miniature circuit breaker rated 16 A, 400 V AC, Type A, with breaking capacities of 10 kA, 20 kA, 15 kA (DC), and 5 kA; this is a current production part.

Mounts via the quick assembly system in any position. Occupies 4 width units (72 mm wide, 90 mm tall, 76 mm deep, 70 mm installation depth). IP20 with conductors connected; touch protection and sealable. Halogen-free and silicon-free — relevant for cleanroom or food-industry panels.

Rating details

Type A tripping characteristic trips on short-circuit and overload with a more sensitive magnetic threshold than Type B or C — suited for semiconductor protection or long cable runs. Rated for 50/60 Hz. Humidity limits to 95 % at 55 °C, tapering to 35 % at 75 °C. Overvoltage category III.

Among the 5SY4 series, this 16 A 4-pole Type A sits between higher-current and lower-current siblings. The Type A characteristic — with its lower magnetic pickup — sets it apart from the more common Type B or C variants in the same frame. For a direct drop-in check, cross-reference the rating plate: any peer with identical poles, current, trip curve, and breaking capacity will fit the same footprint, but the tripping behavior must match your load.

Current production run; no last-time-buy schedule in evidence.

Frequently asked questions

What wire sizes does the terminal accept?

Solid or stranded copper from 0.75 mm² to 35 mm².

MPN