Skip to main content
Siemens 5SY4420-7 — 4-Pole MCB (DIN Rail)

SENTRON 5SY4420-7 4-Pole C20A MCB, 76mm Depth

MPN5SY4420-7
Active

SENTRON 5SY4420-7, 4-pole C20A miniature circuit breaker, 20 A rated, 10/20 kA breaking capacity, 76 mm depth.

$338.66Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4420-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4420-7 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SY4420-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY4420-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4420-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4420-7 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.7 W

Product details

Visual Verification – What to Check on Arrival

The 5SY4420-7: Fake until proven real – start with the sealable housing and the halogen-free marking. Both are factory-identifiers that re-markers routinely omit. The product designation and brand should be laser-engraved, not ink-stamped; surfaces must be free of solvent wipe marks. The 76 mm depth and 72 mm width correspond to 4 modular units on a DIN rail – a common footprint. Cross-check the physical dimensions against the labelled value; any deviation suggests a re-label from a smaller-frame part.

Panel Fit & Derating

Mounts in any position and uses the quick assembly system. The part is silicon-free – no risk of silicone outgassing near sensitive contacts or optics.

Compliance & Sourcing

Designed to IEC/EN 60898-1, IEC/EN 60947-2, and UL1077 – covers both domestic and light-industrial installations. No official L* successor is available; verify qty and lead time with your distributor before committing to a BOM line.

Frequently asked questions

What is the depth of the 5SY4420-7?

The depth is 76 mm. With connected conductors it protrudes to 70 mm installation depth at the DIN rail clip.

What is the width of the 5SY4420-7?

The width is 72 mm, which is 4 modular units.

What compliance standards does the 5SY4420-7 meet?

It meets IEC/EN 60898-1, IEC/EN 60947-2, and UL1077. This combines household and industrial breaker standards plus U.S. supplementary protector listing.

MPN
5SY4420-7