Siemens 5SY4420-6 — 4-Pole MCB (DIN Rail)

Siemens 5SY4420-6 SENTRON 4-Pole MCB, B-Curve 20 A, 10/20 kA

MPN5SY4420-6
Active

Siemens SENTRON 5SY4420-6, 4-pole miniature circuit breaker, B-curve, 20 A rated at 35 °C, 10/20 kA breaking capacity, 4 MW DIN-rail mount.

$338.66Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4420-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4420-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY4420-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-220 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY4420-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4420-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

Breaking capacity and trip curve

The 5SY4420-6 carries a dual breaking-capacity rating: 10 kA per EN 60898 for general-distribution duty, and 20 kA per IEC 60947-2 for industrial panel applications where the prospective fault current is higher. The B-curve characteristic (tripping between 3 and 5× rated current) is the standard choice for resistive and general-purpose loads — lighting, small transformers, control circuits — where inrush is low and fast magnetic trip on short-circuit is wanted.

Temperature derating in the panel

Rated current is 20 A at 35 °C ambient. The SENTRON derating table is explicit: 19.04 A at 40 °C, 18.54 A at 45 °C, 18.04 A at 50 °C, 17.5 A at 55 °C, and 16.96 A at 60 °C. If the breaker sits in a crowded enclosure with multiple heat sources, use the 40 °C or 50 °C column for the continuous-load budget — the thermal-magnetic element responds to internal temperature, not just the nameplate value.

DIN-rail fit and wiring

Four modular-width units (72 mm wide) on a standard 35 mm DIN rail. Depth is 76 mm, height 90 mm. The quick-assembly system snaps on without tools; mounting position is any orientation. Combined terminals top and bottom accept the supply from either end — no need to flip the breaker for top-feed vs bottom-feed. IP20 with conductors connected; overvoltage category III, pollution degree 3.

Frequently asked questions

Can the 5SY4420-6 be used for DC applications?

The 5SY4420-6 is rated for AC voltage only (400 V AC, 50/60 Hz). There is no DC voltage rating in the spec — this breaker is designed for AC distribution circuits, not DC bus or battery strings.