Siemens 5SY4440-6KK11 — 4-Pole MCB (DIN Rail)

Siemens 5SY4440-6KK11 SENTRON MCB, 4P 40A B-curve, 10/15 kA

MPN5SY4440-6KK11

Siemens SENTRON 5SY4440-6KK11 miniature circuit breaker, 4-pole, 40 A rated, B tripping characteristic, breaking capacity 10 kA per EN 60898 / 15 kA per IEC 60947-2, designed for railway applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4440-6KK11 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4440-6KK11 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC40 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY4440-6KK11 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-215 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY4440-6KK11 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4440-6KK11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

The 5SY4440-6KK11 carries a 40 A rated current at 35 °C ambient. Above that, the thermal trip element derates: 38.4 A at 40 °C, 37.6 A at 45 °C, 36.76 A at 50 °C, 35.92 A at 55 °C, and 35.04 A at 60 °C. For a panel running hot — say 50 °C inside the enclosure — the continuous load limit drops to about 36.8 A, not the faceplate 40 A.

Breaking capacity — dual-rated for the standard in use

The higher figure under 60947-2 reflects the standard's allowance for the part's actual performance in a defined upstream impedance. For a site engineer coordinating with an upstream 25 kA rated MCCB, the 15 kA figure gives more headroom in the selectivity study. The B-curve restricts let-through energy to Energy Limitation Class 3, which helps downstream components survive a fault.

Panel fit — 4 MW, quick assembly

Installation depth is 70 mm; total depth 76 mm.

Frequently asked questions

What is the breaking capacity of 5SY4440-6KK11?

Rated 10 kA per EN 60898 and 15 kA per IEC 60947-2, giving the higher figure for coordination studies under the industrial standard.

Where can I buy 5SY4440-6KK11 and get a price?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Will 5SY4440-6KK11 drop into a panel designed for 5SY4140-7?

Both are 4-pole SENTRON MCBs on the same DIN-rail footprint, so mechanical fit is identical. The difference is rating: the 5SY4140-7 carries a lower current — verify your load before substituting.

MPN
5SY4440-6KK11