Skip to main content
Siemens 5SY7510-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY7510-7 MCB, C-curve 2-pole 1P+N, 15/30 kA

MPN5SY7510-7
Active

Siemens SENTRON, 5SY7510-7, miniature circuit breaker, 2-pole (1P+N), C characteristic, 15 kA (EN 60898) / 30 kA (IEC 60947-2), 230 V AC, 36 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7510-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY7510-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY7510-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY7510-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Integrator's spec recap — 5SY7510-7

That neutral-switching feature matters for installations where an isolated neutral is required after the breaker opens, typical in single-phase sub-distribution or machine supply panels where you want both conductors positively disconnected. The breaker is rated for 230 V AC and carries a 15 kA breaking capacity per EN 60898, with a higher 30 kA rating per IEC 60947-2 for industrial panel duty where the prospective fault current is higher. For DC circuits it is rated 60 V at 15 kA per IEC 60947-2.

Certified to IEC / EN 60898-1 and IEC / EN 60947-2, plus UL 1077. Halogen-free and silicon-free construction. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz. The sealable design allows lockout-tagout application. Energy limitation class 3.

Frequently asked questions

What is the breaking capacity of 5SY7510-7?

15 kA per EN 60898 and 30 kA per IEC 60947-2. At DC (60 V) it is rated 15 kA per IEC 60947-2. Under UL 1077 it carries 5 kA.

Will 5SY7510-7 drop into a panel specified around 5SY4140-7 without rewiring?

The 5SY7510-7 is a 2-pole (1P+N) breaker with neutral switching, while the 5SY4140-7 is a 1-pole design. Both share the same 36 mm width per pole (2 MW for the 2-pole) and DIN-rail mounting, but the neutral-switching requirement and pole count differ — verify the panel's wiring diagram before substituting.

Where can I buy 5SY7510-7 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SY7510-7