6EP4135-0GL00-0AY0
Siemens 6EP4135-0GL00-0AY0
MPN6EP4135-0GL00-0AY0
Active
SITOP BAT1600 EX 24 V DC 12 Ah Pb battery module with maintenance- free closed lead-acid battery for SITOP UPS1600
$209.55Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jun 2026
Specifications
| Parameter | Value |
|---|---|
| Type of electrical connection | screw-type terminals |
| Output voltage at DC rated value | 24 V |
| Charging current maximum | 3 A |
| Output current rated value | 40 A |
| For power supply unit | 1 screw terminal each for 0.5 ... 16 mm² for + BAT and - BAT |
| Depth of the enclosure | 138 mm |
| Width of the enclosure | 225 mm |
| Height of the enclosure | 156 mm |
| Wall mounting | Yes |
| Mounting height | 256 mm |
| S7 rail mounting | No |
| Installation width | 225 mm |
By ambient temperature11 ▾
| Parameter | Value |
|---|---|
| At 20 °C typical | 4 y |
| At 30 °C typical | 2 y |
| At 40 °C typical | 1 y |
| At 50 °C typical | 0.5 y |
| At 0 °C recommended | 28 V |
| At 10 °C recommended | 27.8 V |
| At 20 °C recommended | 27.3 V |
| At 30 °C recommended | 26.8 V |
| At 40 °C recommended | 26.6 V |
| At 50 °C recommended | 26.3 V |
| At -10 °C recommended | 28 V |
All specifications+31 ▾
| Parameter | Value |
|---|---|
| Standard rail mounting | No |
| Ambient temperature during storage | Along with the storage and operating temperature, other factors such as the duration of the storage period and the charge status during storage have a decisive influence on the possible useful life. Batteries should therefore be stored as briefly as possible, always fully charged, and within the temperature range 0 to +20 °C. |
| CE marking | Yes |
| UL approval | No |
| CSA approval | No |
| Shipbuilding approval | available soon |
| Top | 50 mm |
| ATEX | Yes |
| Left | 0 mm |
| IECEx | Yes |
| Right | 0 mm |
| Bottom | 50 mm |
| DNV GL | No |
| Typical | capacity falls to 80 % of original capacity (according to EUROBAT) |
| During storage | -20 ... +40 °C |
| Number of cells | 2 |
| Battery capacity | 12 A·h |
| During operation | -15 ... +50 °C |
| During transport | -20 ... +50 °C |
| Mounting | Wall mounting |
| Other information | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) |
| Operating data note | For storage, mounting and operation of lead-acid batteries, the relevant DIN/VDE regulations or country-specific regulations (e.g. VDE 0510 Part 2/EN 50272-2) must be observed. You must ensure that the battery site is sufficiently ventilated. Possible sources of ignition must be at least 50 cm away. |
| Protection class IP | IP20 |
| Product component included | 2x Maxi Fuse 50 A/32 V |
| cCSAus, class 1, division 2 | No |
| Design of the overload protection | Valve control |
| Operating resource protection class | Class III |
| Display version for normal operation | Three-color: green = Buffer ready; yellow = Buffer endangered; red = Buffer not possible |
| For control circuit and status message | 1 screw terminal each for 0.2 ... 2.5 mm² |
| American bureau of shipping europe ltd. | No |
| Relative temporary capacity loss at 20 °C in a month typical | 3 % |