Skip to main content
Delta DOP-107BV — HMI Operator Interfaces

Delta DOP-107BV HMI Panel, 7", Cortex-A8 800 MHz

MPNDOP-107BV

Delta DOP-107BV, 7-inch HMI touch panel, ARM Cortex-A8 800 MHz, 800 x 480, 256 MB RAM, IP65 / NEMA4 / UL Type 4X indoor, 24 VDC powered.

$133.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

DOP-107BV — Mechanical
ParameterValue
Weight0.7 kg
DOP-107BV — Other specifications
ParameterValue
MCUARM Cortex-A8 (800MHz)
CoolingNature air circulation
Back lightLED Back Light
WaterproofIP65 / NEMA4 / UL Type 4X (indoor use only)
RAM (Bytes)256 Mbytes
Product type7" Inch HMI Touch Panel Screen
Flash ROM (Bytes)256 Mbytes
Voltage enduranceA500V for 1 minute (between charging DC24 terminal and FG terminals)
Resolution (Pixels)800 x 480
Storage temperature-20 C ~ 60 C
Operation temperature0 C ~ 50 C
Dimensions (L x w x h)3.35 cm x 21.5 cm x 16.1 cm

Product details

Definition and panel role

The Delta DOP-107BV is a 7-inch HMI touch panel screen in Delta's DOP operator-interface line, built around an ARM Cortex-A8 running at 800 MHz with 256 Mbytes each of working RAM and flash ROM — meaning the runtime has the headroom for mid-complexity recipes, multi-screen navigation, and modest logging without forcing a jump to a larger 10-inch class. Display resolution is 800 x 480 pixels on an LED backlit panel sized for cabinet-door cut-outs typical of small machine control stations rather than full SCADA overview screens.

Environment and panel-side fit

Rated IP65 / NEMA4 / UL Type 4X for indoor use, so the front face tolerates routine wipe-downs on a factory floor but is not specified for outdoor or washdown cabinets — pair it with a panel-rated enclosure and confirm the gasket compression at the cut-out during commissioning. Operating temperature spans 0 C to 50 C and storage -20 C to 60 C; cooling is natural air circulation, so leave clearance above and below the chassis for convective flow and don't bury the unit behind heat-generating devices.

Frequently asked questions

When sourcing DOP-107BV, what is the closest functional second-source — DOP-110CS?

No — the DOP-110CS is the same family but a different panel size (1024 x 600 resolution vs 800 x 480, ~1.33 kg vs 0.7 kg, larger chassis), so it is not a pin-compatible or panel-cut-out drop-in. Plan it as a separate part number in the BOM rather than a substitute.

MPN
DOP-107BV