Integration Notes
The H TYPE DC input accepts 24 VDC nominal from the field — verify polarity before wiring; the slim form factor means terminal spacing is tight, so use a small slotted driver for the spring-cage clamps. The 20 I/O count covers small machine cells or analog-signal concentration; leave headroom in the backplane power budget if adding expansion modules.