Delta VFD015CB23A-20 — AC Drive (VFD) 240V

Delta VFD015CB23A-20 VFD, 1.5 kW, 230 V 3-PH

MPNVFD015CB23A-20

Delta C200 Series VFD015CB23A-20, Economy Vector Control Drive, 1.5 kW / 2 HP, 230 V 3-phase input, IP20 wall-mount, 12 A line current.

$359.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

VFD015CB23A-20 — Mechanical
ParameterValue
Weight1.5 Kg
VFD015CB23A-20 — Other specifications
ParameterValue
VersionA=Wall mount
C200 seriesCB
Series nameVFD = Variable Frequency Drive
Product typeEconomy Vector Control Drive C200 Series
IP protection20: IP20/UL Open Type
Input current12
Input voltage23: 230 V 3-PHASE
Control method1: V/F, 2: SVC, 3: VF+PG, 4: FOC+PG
Torque limit max.200% torque current
Applicable motor capacity015:2 HP(1.5 kW)
Max. output frequencynormal duty: 0.00~600.00Hz; Heavy duty: 0.00 ~ 300.00 Hz

Product details

1.5 kW on a 230 V three-phase feed, wall-mounted

The Delta VFD015CB23A-20 is the 1.5 kW / 2 HP frame in the C200 economy vector-control line, sized for a 230 V three-phase input drawing 12 A line current — the right size for small pumps, conveyors, fans and mixers on a 240 V three-phase service. It runs four control modes from plain V/F through sensorless vector (SVC) up to closed-loop FOC with an encoder (PG), so the same drive that starts a fan on V/F can later be re-tuned for a conveyor needing speed-hold at low rpm.

What the headroom ratings mean on the load side

200 % torque current is the overload budget — the drive delivers double rated current long enough to break away a loaded conveyor or pump from standstill without tripping. Output frequency reaches 600.00 Hz in normal duty and 300.00 Hz in heavy duty, which covers high-speed spindles and constant-torque conveyor service in the same unit, with the heavy-duty cap the figure to apply when the load is held at rated torque across the speed range.

Lifecycle and the panel-side sourcing picture

Lifecycle is recorded as current production with no PCN or successor on file — the C200 series remains the economy vector frame in Delta's 240 V three-phase line, with the 0.75 kW three-phase sibling in the same footprint ready to drop in where the motor on the BOM is smaller. For a panel-builder, that means the drive joins the same procurement cycle as the contactors and breakers in the cubicle, not a separate expedite.

Frequently asked questions

Will VFD015CB23A-20 drop into a panel that was specified around the 0.75 kW single-phase frame?

No — the 0.75 kW single-phase unit (VFD007CB21A-20) takes a 230 V single-phase feed, not three-phase, so the input wiring, breaker sizing and line current rating all differ. The 0.75 kW three-phase sibling VFD007CB23A-20 shares the same three-phase 230 V input and 1.5 Kg form factor but at half the motor rating; the question is whether the connected motor is 1.5 kW or 0.75 kW, not which feed the cabinet has.

What motor size and input feed does VFD015CB23A-20 match?

It is rated for a 1.5 kW / 2 HP motor on a 230 V three-phase input drawing 12 A. The four control modes span V/F, sensorless vector, V/F with PG and FOC with PG feedback.