Skip to main content
Omron D4A0500N

Omron D4A0500N Limit Switch Box, EN50041, 2NO/2NC, IP67, Sta

MPN D4A0500N

Omron D4A-N series limit switch box, EN50041 body style, stainless steel, IP67, 2NO/2NC contacts, 5 A @ 600 V AC / 5 A DC, plug-in configuration, CSA/UL listed.

$83.82 – $121.66 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

D4A0500N specifications
ParameterValue
Contact form2NO/2NC
IP ratingIP67
MaterialStainless Steel
Body configurationPlug-In

Product details

The Omron D4A0500N is a limit switch box from the D4A-N series, built to the EN50041 body standard with a stainless steel housing. It carries 2NO/2NC contacts rated for 5 A at 600 V AC and 5 A DC — enough for direct switching of small motor starters or pilot-duty solenoids in a control panel. The plug-in body configuration means the switch head and body separate from the base wiring, so a replacement swaps in without pulling new cable through the conduit.

IP67 means the housing is dust-tight and survives immersion in 1 m of water for 30 minutes — suitable for washdown zones in food processing or outdoor conveyor lines where hosing is routine. The NEMA enclosure ratings go further: 3, 4, 4X, 6P, 12, and 13 cover rain, sleet, hose-down, corrosion-resistant, and oil-tight environments. That NEMA 4X and 6P pairing, combined with the stainless steel body, tells you this box is built for corrosive washdown areas where a painted die-cast housing would pit within months. The 5 A contact rating at 600 V AC and 5 A DC governs what loads this switch can break directly. For a 120 VAC pilot light or a small contactor coil, 5 A is ample. For a 1 HP motor at 480 V (roughly 1.4 A FLA), the switch can handle it, but the inductive kick from the motor starter coil should be suppressed with a snubber across the contacts — standard practice for any limit switch driving a contactor. The 2NO/2NC contact form gives you one normally-open and one normally-closed pair, which is the standard arrangement for a safety interlock circuit: the NC pair monitors the guard position, the NO pair signals the PLC. Operating temperature spans -40 °F to 212 °F. That -40 °F low end covers freezer-warehouse applications; the 212 °F high end is near boiling, so the switch can sit on a steam-jacketed vessel or near a drying oven without derating. The two mounting holes are spaced 60 mm vertically and 30 mm horizontally — a standard EN50041 footprint that matches existing cutouts in most European-style machine frames.

MPN