Skip to main content
Omron E5CC-RX2ABM-004

Omron E5CC-RX2ABM-004 Temp Controller, 3 Relay, RS-485

MPN E5CC-RX2ABM-004
Active

Omron E5CC-RX2ABM-004 Process / Temperature Controller, 3 Relay Outputs, RS-485 Communications, Spring Terminal, 100-240 VAC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5CC-RX2ABM-004 specifications
ParameterValue
SeriesE5CC
Output signalRelay (3)
Supply voltage100 to 240VAC
IP ratingIP66
ProtocolRS-485 (CompoWay/F, Modbus)
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.265 lb (120.2 g)
PackageBox
Control methodOn/Off, Proportional (PID)

Product details

At a glance

The E5CC-RX2ABM-004: Communication is via RS-485 supporting CompoWay/F and Modbus protocols, making it straightforward to integrate into existing PLC-based lines. The front panel carries a dual-color LCD backlit display with two rows of four characters each.

When to pick this over the E5CC-CX3A5M-005

If your BOM calls for three relay outputs and spring terminal connections, this is the direct pick. The E5CC-CX3A5M-005 carries an additional analog output and uses screw terminals, but swaps one relay for that analog channel — so it cannot support three independent on/off zones the way this can. Termination preference drives the choice: the spring-clamp variant (this one) eliminates torque-checking during panel build and resists loosening from vibration; the screw variant (CX3A5M-005) requires a screwdriver and occasional re-torque in service. Otherwise, the controller core — input ranges, display, IP rating, communication, PID algorithm — is identical across the two. Panel cutout and wiring footprint match, so a swap is possible without re-punching the panel, though you must account for the output count difference.

For maintenance spares holding, this remains a stable line item. If you are backfilling an existing panel, confirm the output count and termination style; the panel cutout and wiring footprint are standard across the E5CC series.

Mounting and wiring considerations

Panel cutout is a 45 mm square; the controller slides in from the front and clamps with the provided bracket. IP66 rating requires the front gasket to seat cleanly against a flat panel surface — no raised paint or burrs.