Skip to main content
Omron E5EC-QX4DBM-011

Omron E5EC-QX4DBM-011 Temperature Controller, 24VAC/DC, PID

MPN E5EC-QX4DBM-011
Active

Omron E5EC series, E5EC-QX4DBM-011, Temperature Controller, relay + voltage (external SSR) outputs, 24VAC/DC supply, PID control, IP66 front panel.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5EC-QX4DBM-011 specifications
ParameterValue
SeriesE5EC
Output signalRelay (5), Voltage (External SSR)
Supply voltage24 VAC/DC
IP ratingIP66
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.463 lb (210.01 g)
PackageBox
Control methodOn/Off, Proportional (PID)

Product details

What the E5EC-QX4DBM-011 covers — and what that means for a swap

The Omron E5EC-QX4DBM-011 is a panel-mount temperature controller that accepts nearly any common sensor input: RTD, thermocouple types B, E, J, K, L, N, PLII, R, S, T, U, W, plus 0–20 mA or 0–10 VDC analog signals. That means one part number can replace a failed controller on a plastic extruder (type J), a heat-treat furnace (type R), or a cold-storage loop (Pt100 RTD) without changing the BOM line. The input range spans -200°C to 2300°C, so it handles cryogenic monitoring up through high-temperature kilns. Control method is selectable between On/Off and full PID with autotune. The PID loop is what you want for processes that can't tolerate overshoot — oven zones, packaging seal bars, injection mold cavities. On/Off is fine for tank heaters or alarm-only circuits. Outputs are a mix: one relay (5 A typical) and a voltage pulse for driving an external solid-state relay. That voltage output is the key difference from the relay-only sibling — if your load cycles frequently (heater contactor on a fast PID loop), you route the SSR output to an external SSR and save the relay contacts from early weld.

Supply, mounting, and environment — the fit check

Panel cutout is 92 mm × 45 mm rectangular — the standard 1/4 DIN footprint. Spring-cage terminals on the back; strip length around 8 mm, no screw tightening needed. IP66 on the front face means it survives washdown in food or beverage lines; the rear is not sealed, so mount it in a dry enclosure. If the panel sits next to a hot oven or in direct sun, check the internal temperature rise — the controller itself generates a few watts, so derate if ambient exceeds 50°C.

Heater fault detection — what it catches

Built-in heater fault detection monitors the load current via an external CT (not included) and flags a broken heater or SSR short. On a multi-zone oven or hot-runner system, that alarm can trigger a visual indicator on the tri-color LCD display before the product quality drifts.

MPN
E5EC-QX4DBM-011