Skip to main content
Omron E5EC-RX2DBM-008

Omron E5EC-RX2DBM-008 Temperature Controller

MPN E5EC-RX2DBM-008
Active

Omron E5EC series temperature controller, E5EC-RX2DBM-008, 4 relay outputs, 24VAC/DC supply, RS-485, PID/On-Off control, IP66 front panel.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5EC-RX2DBM-008 specifications
ParameterValue
SeriesE5EC
Output signalRelay (4)
Supply voltage24 VAC/DC
IP ratingIP66
ProtocolRS-485
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.463 lb (210.01 g)
PackageBox
Control methodOn/Off, Proportional (PID)

Product details

The Omron E5EC-RX2DBM-008 is a panel-mount temperature controller from the E5EC series, designed for process and temperature control loops where you need a rugged, sealed front end. It accepts a wide range of sensor inputs — RTD and thermocouple types B, E, J, K, L, N, PLII, R, S, T, U, W — covering the span from -200°C to 2300°C, plus 0–20 mA and 0–10 VDC linear signals. That means it can handle everything from a cryogenic bath to a furnace zone on the same unit, just by reconfiguring the input type. Control is via On/Off or proportional (PID) methods, with four relay outputs for driving contactors, solenoids, or alarms. The 24 VAC/DC supply voltage is common in industrial panels, and the spring-cage terminals save wiring time compared to screw clamps — no re-torquing after thermal cycling. The IP66-rated front panel means it withstands washdown and dusty environments, so it's at home on a food-processing line or a lube-oil skid where hoses are part of the daily routine. The rectangular 92.00 mm x 45.00 mm panel cutout is the standard 1/4 DIN footprint — drops into existing punch-outs without adapter plates.

The four relay outputs are rated for switching loads directly — typical use is driving a contactor coil for a heater or a solenoid valve for coolant. With PID control, the controller can manage both heating and cooling outputs if you assign two relays to that job, though the unit itself doesn't have a dedicated dual-output mode label; that's a programming choice in the PID algorithm. RS-485 communications let you pull temperature data into a PLC or SCADA system over Modbus. The tri-color LCD display shows three rows of four characters each, with the top row at 0.710" (18.00 mm) height — readable from a few feet away on a panel door. Heater fault detection monitors current draw on the load side and flags a broken heater element or blown SSR. That's a real time-saver on electric heater banks where a single failed element can drop process temperature without tripping a breaker.

MPN
E5EC-RX2DBM-008