Skip to main content
Omron MY4N-D2 DC125

Omron MY4N-D2 DC125 General Purpose Relay, 4PDT, 125 VDC

MPN MY4N-D2 DC125

Omron MY4N-D2 DC125 general purpose relay, plug-in, 4PDT, 125 VDC coil, 3 A max switching, RoHS.

$48.12 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MY4N-D2 DC125 specifications
ParameterValue
Coil voltage125 VDC
Temp operating max70 °C
Temp operating min-55 °C

Product details

What you're swapping into the socket

The Omron MY4N-D2 DC125 is a plug-in general purpose relay in the MY series, built around a 4PDT contact arrangement with a 125 VDC coil — four poles in one package, so a single socket handles a logic interlock, a status return, and two spares without stacking two DPDT relays. It draws roughly 0.9 W to hold the armature in, which matters on a 125 VDC rail — the DC coil is the slower-dropout side of this part versus the AC variants, so check the dropout time budget on any timing-sensitive interlock.

Contact ratings and what they govern

Maximum switching current is 3 A, with switching voltage rated to 250 VAC or 125 VDC — on the resistive side the contact carries 3 A at 220 VAC or 24 VDC, which lands at 660 VA / 72 W of switching power. Inductive loads drop the envelope sharply: 0.8 A at 220 VAC and 1.5 A at 24 VDC, with inductive switching power capped at 176 VA / 36 W. The relay will switch the resistive number, but a solenoid, contactor coil, or DC motor winding needs to be sized against the inductive figures, not the headline 3 A. Minimum load is rated 1 mA at 1 VDC, so the same contact that powers a small solenoid still closes cleanly on a low-level logic return — useful when one relay is doing double duty as a pilot-duty output and a status feedback into a PLC input.

Operating envelope and panel placement

Operating temperature spans -55 to 70°C, which covers unheated cabinets and most outdoor enclosures without derating — the relay drops into a standard MY-series socket, so field replacement is a pull-and-push on the existing DIN-rail or panel-mount base.

Lifecycle status and compliance posture

RoHS compliance is confirmed, so the part ships into builds destined for the EU and other jurisdictions enforcing the restriction list; the MRO buyer specifying this for a retrofit does not need a separate compliance waiver for the lead-free build standard.

MPN
MY4N-D2 DC125