Skip to main content
Delta VFD004CB21A-20

Delta VFD004CB21A-20 VFD, 0.4 kW, 230 V 3-phase

MPN VFD004CB21A-20

Delta C200 series VFD004CB21A-20 economy vector control AC drive, 0.4 kW / 0.5 HP, 230 V 3-phase input, IP20 wall-mount, V/F and SVC control.

$287.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

VFD004CB21A-20 specifications
ParameterValue
Input voltage23: 230 V 3-PHASE
Weight1.5 Kg
Control method1: V/F, 2: SVC, 3: VF+PG, 4: FOC+PG

Product details

What buyers sourcing this line actually need to confirm

The Delta VFD004CB21A-20 sits in the C200 economy vector line as a 0.4 kW (0.5 HP) wall-mount drive, sized for 230 V 3-phase input and rated for up to 600 Hz output in normal duty, which puts it squarely in the small-frame 240 V VFD slot on a control-panel BOM. It carries the standard C200 control set — V/F, sensorless vector (SVC), V/F with PG feedback, and FOC with PG feedback — so the same drive covers fan/pump V/F work on one end and a closed-loop vector spindle or winder on the other without changing the panel footprint.

Ratings and what they mean for fit

The 7.2 A input current and 200% torque-current limit define the overload ceiling this drive will deliver into a motor: 200% torque current is the transient capability for accel/decel ramps, not the continuous rating — duty cycle and motor thermal limit matter more than the peak number for sizing. Output frequency tops out at 600 Hz in normal duty and 300 Hz in heavy duty, which means a 0.5 HP motor on a high-speed spindle or a small blower running past 200 Hz is in normal-duty territory, while constant-torque conveyors and mixers stay inside the heavy-duty map.

Sourcing posture and lifecycle read

No official second-source or successor is recorded for this specific code. The same C200 platform covers higher-horsepower slots in the family — 3.7 kW / 5 HP on the 230 V 3-phase rail and 4.0 kW / 5.5 HP plus 5.5 kW / 7.5 HP on the 460 V 3-phase rail — but those are different ratings, different input currents (20 A, 15.5 A, 17 A respectively), and not direct drop-ins for a 0.4 kW panel position.

MPN
VFD004CB21A-20