Omron E5CC-TQX3A5M-001

Omron E5CC-TQX3A5M-001 Temperature Controller, Relay/Voltage

MPN E5CC-TQX3A5M-001
Active

Omron E5CC-T series, E5CC-TQX3A5M-001, Process/Temperature Controller with Relay (3) and Voltage (External SSR) output, dual-color LCD, IP66, 100-240VAC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5CC-TQX3A5M-001 specifications
ParameterValue
SeriesE5CC-T
Output signalRelay (3), Voltage (External SSR)
Supply voltage100 to 240VAC
IP ratingIP66
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.265 lb (120.2 g)
PackageBulk
Control methodOn/Off, Proportional (PID)

Product details

Dual-Output Process Controller with Event Input and Heater Fault Detection

This Omron E5CC-TQX3A5M-001 is a panel-mount process/temperature controller from the E5CC-T series, accepting inputs from RTD and a wide range of thermocouple types (B, E, J, K, L, N, PLII, R, S, T, U, W) as well as 0–20 mA or 0–10 VDC analog signals. It offers both relay (3) and voltage (external SSR) output types, giving flexibility for driving contactors or solid-state relays directly. The dual-color LCD backlit display shows two rows of four characters each, with 0.600" and 0.280" character heights for process value and setpoint. IP66 rating makes it suitable for washdown or dusty environments if properly gasketed. Built-in event input and heater fault detection expand monitoring capability without an additional logic module. Control method supports On/Off or proportional PID with auto-tuning expected from the series family. Mounting fits a standard 45×45 mm panel cutout with screw terminals accepting 100–240 VAC supply.

Peer Comparison: E5CC-CX3A5M-004 — What Changes

The frequently cross-shopped E5CC-CX3A5M-004 shares the same form factor, panel cutout, and screw terminals, but carries two functional differences: it replaces the relay+voltage output with an analog output and includes RS-485 communications (CompoWay/F, Modbus). It also lacks heater fault detection, though it retains event input. If your BOM requires heater fault detection or the ability to switch loads via relay/SSR without an analog output, the -TQX3A5M-001 is the correct choice. The -CX3A5M-004 works where a proportional analog signal and digital communication to a PLC are needed. Physical swap is possible but electrical re-termination is required.

Sourcing & Lifecycle: Current Production, Order-to-RFQ

Quote against an RFQ for current pricing and lead time. No last-time-buy or obsolescence concerns.

MPN
E5CC-TQX3A5M-001