Mitsubishi Electric AJ65SBTB1-16DT — Digital Output Modules

Mitsubishi AJ65SBTB1-16DT Remote I/O, 8 In/8 Out, DC 24V

MPNAJ65SBTB1-16DT

Mitsubishi AJ65SBTB1-16DT Remote I/O Station, 8 DC Inputs + 8 Transistor Sink Outputs, DC 24V, 118 × 40 mm, Mature Lifecycle.

$182.00 – $452.96Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

AJ65SBTB1-16DT key specifications
ParameterValue
Station typeRemote I / O station
Withstand voltageBetween DC external terminal and ground: AC 500 V for 1 minute
Rated load voltageDC 24V
Rated input voltageDC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 26.4 V)
Over voltage categoryII or less
ON voltage (ON current)14 V or more / 3.5 mA or more
Used load voltage rangeDC 19.2 to 26.4 V (ripple ratio within 5%)
OFF voltage (OFF current)6 V or less / 1.7 mA or less
Unit power supply voltageDC 20.4 to 26.4 V (ripple ratio within 5%)
Maximum voltage drop during ONDC 0.3 V or less (TYP.) 0.5 A, DC 0.6 V or less (MAX.) 0.5 A
Output section external power supply voltageDC 19.2 to 26.4 V (ripple ratio within 5%)
Current50 mA or less (24 VDC, all points ON)

All specifications

AJ65SBTB1-16DT additional specifications
ParameterValue
Rated input currentAbout 7 mA
Maximum load current0.5 A / 1 point, 2.4 A / 1 common
Leakage current at OFF0.25 mA or less
Maximum inrush current1.0 A less than 10 ms
Installation locationIn the control panel
External wiring connection methodCommunication unit, Unit power supply unit: 7 points 2-piece terminal block (M3 screw) I / O power supply unit, input / output unit: 18 points Direct mounting terminal block (M3 screw)
Input response time OFF → ON1.5 ms or less (24 VDC)
Output response time OFF → ON0.5ms or less
Storage ambient temperature-20 to 75 ° C
Operating ambient temperature0 to 55 ° C
Pollution degree2 or less
Storage ambient humidity10 to 90% RH, non condensing
Ambient operating humidity10 to 90% RH, non condensing
When there is continuous vibrationFrequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2
Depth40 mm
Width118 mm
Shipping weight1.2 Kg
External dimensions height50 mm
Mass0.18 Kg
ON → OFF1.5 ms or less (resistance load)
Input formatDC input (plus common type)
Common method16 points 1 common (terminal trapezoid 1 wire type)
Output formatTransistor output (sink type)
Use elevation0 to 2000 m
Use atmosphereNo corrosive gas
Input resistanceAbout 3.3 kΩ
Protection gradeIP2X
Impact resistanceMeets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)
Estimated lead timeUsually ships in 1 - 10 working days.
Protection functionOverload protection function, overvoltage protection function, overheat protection function
Insulation resistanceDC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 MΩ or more
Input isolation methodPhotocoupler isolation
Number of input points8 points
Number of output points8 points
Output isolation methodPhotocoupler isolation
Number of occupied stations1 station
Maximum number of simultaneous input points100%

Product details

Mitsubishi AJ65SBTB1-16DT is a remote I/O station that packs 8 DC inputs (plus common type) and 8 transistor sink outputs into a compact 118 mm wide, 40 mm deep housing. It draws 50 mA or less from the 24 VDC bus with all points ON—efficient for crowded panels.

Station type is a remote I/O node with 16 points per common terminal (trapezoid 1-wire terminals). Input resistance sits around 3.3 kΩ; rated input current is 7 mA at 24 VDC. Outputs handle 0.5 A per point with a 2.4 A common limit—keep that derating in mind when grouping loads. Install inside the control panel only. No corrosive gas atmosphere—standard industrial cabinet conditions.

This module is in its mature lifecycle phase, meaning stable, ongoing production with consistent availability. Typical lead time runs 1–10 working days. For allocation on larger BOMs, an RFQ locks in supply against your schedule.

Frequently asked questions

What are the key I/O specs?

8 DC inputs (plus common) and 8 transistor sink outputs. Each output is rated 0.5 A, with a 2.4 A common limit.

What is the power draw?

50 mA or less from the 24 VDC supply when all points are ON.

How quickly can I get this part?

Typical lead time is 1–10 working days.

MPN
AJ65SBTB1-16DT