Skip to main content
Mitsubishi Electric AJ65SBTB2N-16R — PLC I/O & Expansion Modules

AJ65SBTB2N-16R CC-Link Remote I/O, 16 Relay Outputs

MPNAJ65SBTB2N-16R

Mitsubishi AJ65SBTB2N-16R CC-Link remote I/O unit, 16 relay outputs, terminal block type, 0.35 kg.

$169.00 – $356.87Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

AJ65SBTB2N-16R key specifications
ParameterValue
Station typeRemote I / O station
Withstand voltageBetween AC external terminal and ground: AC 2830 Vrms / 3 cycles (altitude 2000 m) Between DC external terminals and ground: AC 500 V 1 min
Over voltage categoryII or less
Maximum switching voltageAC 264 V DC 125 V
Unit power supply voltageDC 20.4 to 26.4 V (ripple ratio within 5%)
Rated switching voltage (current)DC 24 V 2A (resistance load) / 1 point, AC 240 V 2 A (cos φ = 1) / 1 point, 8 A / 1 common
Current120 mA or less (24 VDC, all points ON)
Maximum switching frequency3600 times / hour
Installation locationIn the control panel
External wiring connection methodCommunication part, unit power supply part: 7 points 2 piece terminal block (M3 screw) I / O power supply part, input / output part: 34 points Direct mounting terminal block (M3 screw)
Output response time OFF → ON10 ms or less
Storage ambient temperature-20 to 75 ° C

All specifications

AJ65SBTB2N-16R additional specifications
ParameterValue
Operating ambient temperature0 to 55 ° C
Pollution degree2 or less
Storage ambient humidity10 to 90% RH, non condensing
Ambient operating humidity10 to 90% RH, non condensing
When there is continuous vibrationFrequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2
Depth40 mm
Width179 mm
Shipping weight2 Kg
External dimensions height50 mm
Mass0.35 Kg
ElectricalRated switching voltage . current load: 100,000 times or more AC 200 V 1.5 A, AC 240 V 1A (COS φ = 0.7): 100 thousand times or more AC 200 V 1A, AC 240 V 0.5 A (COS φ = 0.35): 100,000 times or more DC 24 V 1A, DC 100 V 0.1 A L / R = 7 ms): 100 thousand times or more
ON → OFF12 ms or less
Use elevation0 to 2000 m
Use atmosphereNo corrosive gas
Impact resistanceMeets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)
Estimated lead timeUsually ships in 1 - 10 working days.
Lifespan mechanicalOver 20 million times
Output common method16 points 1 common (terminal trapezoid 2 wire type)
Insulation resistanceAC external terminal all together and ground, DC external terminal collective to ground: 500 MV DC insulation resistance meter 10 MΩ or more
Number of output points16 points
Output isolation methodRelay insulation
Number of occupied stations1 station
Minimum opening (closing load)DC 5 V 1 mA

Product details

The Mitsubishi AJ65SBTB2N-16R is a CC-Link small type remote I/O unit with 16 relay outputs, arranged as 16 points per common on a terminal block. It serves as a remote I/O station on a CC-Link fieldbus network, occupying 1 station. Rated switching capacity per point: AC 240 V 2 A resistive load (cos φ = 1) or DC 24 V 2 A; total per common is 8 A. Minimum switching load is DC 5 V 1 mA, so light-signal switching is fine. Response time OFF→ON is 10 ms or less; ON→OFF is 12 ms or less. Unit power supply is DC 20.4 to 26.4 V (ripple within 5%). With all 16 outputs ON, the unit draws 120 mA or less from the power supply.

Mounts inside a control panel at 0–2000 m elevation, pollution degree 2 or less, 0–55 °C ambient. External dimensions 179 mm wide x 50 mm high x 40 mm deep. Wiring: 34-point direct mounting terminal block (M3 screws) for I/O and power; communication and unit power use a 7-point two-piece terminal block. Use appropriate screw torque per Mitsubishi guidelines. Meets JIS B 3502 and IEC 61131-2 impact resistance. Withstand voltage: AC 2830 Vrms/3 cycles between external terminals and ground at 2000 m altitude.

Frequently asked questions

What is AJ65SBTB2N-16R's listed mass?

The unit mass is 0.35 kg. Shipping weight is 2 kg.

MPN
AJ65SBTB2N-16R