Skip to main content
Mitsubishi Electric AJ65SBTB2N-16S — PLC I/O & Expansion Modules

Mitsubishi AJ65SBTB2N-16S CC-Link Remote I/O, 16 Triac Out

MPNAJ65SBTB2N-16S

Mitsubishi AJ65SBTB2N-16S, CC-Link small type remote I/O unit, triac output, terminal block, 16 points, 0.6 A per point, 85 mA consumption.

$361.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

AJ65SBTB2N-16S key specifications
ParameterValue
Station typeRemote I / O station
Withstand voltageBetween AC external terminal and ground: AC 2830 Vrms / 3 cycles (altitude 2000 m) Between DC external terminals and ground: AC 500 V 1 min
Maximum load voltageAC 264 V
Over voltage categoryII or less
Unit power supply voltageDC 20.4 to 26.4 V (ripple ratio within 5%)
Load voltage distortion rateWithin 5%
Rated load voltage, frequencyAC 100 to 240 V, 50/60 Hz ± 5%
Maximum voltage drop during ONAC 1.5 Vrms or less (at 0.6 A)
Minimum load voltage . currentAC 50 V 100 mA, AC 100 V 10 mA, AC 240 V 10 mA
Current85 mA or less (24 VDC, all points ON)
Maximum load current0.6 A / 1 point, 4.8 A / 1 common
Leakage current at OFF3 mArms or less (at 200 Vrms at 60 Hz), 1.5 mArms or less (at AC 100 Vrms at 60 Hz)

All specifications

AJ65SBTB2N-16S additional specifications
ParameterValue
Maximum inrush current25 A 10 ms or less
Installation locationIn the control panel
External wiring connection methodCommunication part, unit power supply part: 7 points 2 piece terminal block (M3 screw) I / O power supply part, input / output part: 34 points Direct mounting terminal block (M3 screw)
Output response time OFF → ON1ms or less
Storage ambient temperature-20 to 75 ° C
Operating ambient temperature0 to 55 ° C
Pollution degree2 or less
Surge suppressorCR absorber (0.01 μF + 47 Ω)
Storage ambient humidity10 to 90% RH, non condensing
Ambient operating humidity10 to 90% RH, non condensing
When there is continuous vibrationFrequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2
Depth40 mm
Width179 mm
Shipping weight1.4 Kg
External dimensions height50 mm
Mass0.35 Kg
ON → OFF1 ms + 0.5 cycles or less
Use elevation0 to 2000 m
Use atmosphereNo corrosive gas
Impact resistanceMeets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)
Estimated lead timeUsually ships in 1 - 10 working days.
Output common method16 points 1 common (terminal trapezoid 2 wire type)
Insulation resistanceAC external terminal all together and ground, DC external terminal collective to ground: 500 MV DC insulation resistance meter 10 MΩ or more
Number of output points16 points
Output isolation methodPhotocoupler isolation
Number of occupied stations1 station

Product details

Capabilities at a glance

The AJ65SBTB2N-16S: Each of the 16 outputs handles 0.6 A continuous, 4.8 A per common, with a maximum inrush of 25 A for 10 ms. Rated for AC loads 100–240 V, 50/60 Hz. The on-state voltage drop is ≤1.5 Vrms at 0.6 A. Those numbers fit solenoid valves, contactor coils, or indicator lights – any AC load that stays under the 0.6 A ceiling. Isolation is photocoupler, response time 1 ms or less off→on, 1 ms + 0.5 cycles on→off.

Frequently asked questions

What is the mass of the AJ65SBTB2N-16S?

The unit weighs 0.35 kg.

Can the AJ65SBTB2N-16S replace an FX3S-20MR/ES in the same panel?

No. The AJ65SBTB2N-16S is a CC-Link remote I/O station with 16 triac outputs, while the FX3S-20MR/ES is a PLC. They serve different functions and are not drop-in substitutes.

MPN
AJ65SBTB2N-16S