Skip to main content
Mitsubishi Electric FR-A840-00170-2-60 — AC Drive (VFD) 480V

Mitsubishi FR-A840-00170-2-60 AC Drive, 170A SLD, 480V

MPNFR-A840-00170-2-60

Mitsubishi Electric FR-A840-00170-2-60 AC Drive (VFD) 480V, FR-A800 series, 170A SLD rated current, three-phase 380-500V input, IP20, forced air cooling, with circuit board coating.

$1,274.00 – $3,015.46Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

FR-A840-00170-2-60 — Specifications
ParameterValue
-60With Circuit board coating (3C2), Without Plated conductor
Type-2 = CA
Weight6.7 kg
Product typeInverter FR-A800
Voltage class4 = 400V class
Cooling systemForced air cooling
Standard modelThree-phase 400V class FR-A840
Structure, functionality0 = Standard model
Protective structure (IEC 60529)Enclose type (IP20)
Rated input AC voltage (frequency)Three-phase 380 to 500V 50Hz/60Hz
Permissible AC voltage fluctuation323 to 550V 50Hz/60Hz

Product details

What the 170 A SLD rating means for your motor load

The FR-A840-00170-2-60 carries a 170 A SLD (Super Light Duty) rated inverter current — that's the continuous output current the drive can deliver into a light-duty load like a fan or centrifugal pump without derating. For a typical 480 V motor, that translates to roughly 90-110 kW depending on the application duty cycle. The SLD rating is more generous than the HD (Heavy Duty) rating on the same drive frame, so if your load is a constant-torque conveyor or positive-displacement pump, you'll need to check the HD current curve — the SLD number alone won't guarantee thermal headroom for that duty. Input accepts three-phase 380 to 500 V at 50 or 60 Hz, with permissible fluctuation from 323 to 550 V — wide enough to handle most industrial mains without a step-down transformer.

Circuit board coating and panel fit

Forced air cooling means the heatsink needs clear airflow — minimum clearance above and below per the manual (typically 100 mm). The standard model (-0 suffix) has no built-in brake transistor or EMC filter; if your application needs dynamic braking or conducted emissions compliance, plan for external components.

Frequently asked questions

Will FR-A840-00170-2-60 drop into a panel that was specified around FR-A740-00230-NA without rewiring?

Not directly. The FR-A740-00230-NA is from the A700 series with a different frame size and weight (6.79 kg vs 6.7 kg). The mounting footprint, power wiring terminals, and control I/O layout differ between the A700 and A800 series — expect to rework the panel layout and wiring.

What does the -60 suffix mean on this drive?

The -60 suffix indicates the drive includes circuit board coating per 3C2 (conformal coating for humidity resistance) but does not have plated conductor on the power terminals. It's a standard protective treatment for the electronics, not a heavy-duty corrosion package.

MPN
FR-A840-00170-2-60