FX1N-40MR-D - Mitsubishi Electric
MPNFX1N-40MR-D
End of Life
FX1N series FX1N-40MR-D
$328.00Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jun 2026
Specifications
| Parameter | Value |
|---|---|
| 10 | T200 to T245 46 points (0.01 to 327.67 seconds) |
| Output type (format) | Relay output |
| 1 ms integration type (Capacitor keep) | T246 to T249 4 points (0.001 to 32.767 seconds) * Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving. |
| 100 ms integration type (Capacitor keep) | T250 to T255 6 points (0.1 to 3,276.7 seconds) * Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving. |
| Voltage | 12 to 24 VDC |
| Withstand voltage | When performing the withstand voltage test, make the voltage between each terminal and the ground terminal of the basic unit as follows. Between power supply terminal (DC power supply) and earth terminal: 500 VAC for 1 minute Between output terminal (relay) and earth terminal: AC 1.5 kV 1 min |
| Input signal voltage | DC 24 V ± 10% |
| Voltage tolerance range | DC 10.2 to 28.8 V |
| Inrush current | Up to 25 A 1 ms or less / 24 VDC, 22 A maximum 0.2 ms or less / DC 12 V |
| Input OFF sensitivity current | 1.5 mA or less |
| Input signal current x000 to x007 | 7 mA / 24 VDC |
| Input ON sensitivity current x000 to x007 | 4.5 mA or more |
All specifications+80 ▾
| Parameter | Value |
|---|---|
| Power consumption | Includes 18 W input current (7 mA or 5 mA per point). |
| Power supply fuse | 125 V 3.15 A |
| External power supply | AC 250 V DC 30 V or less |
| Allowable momentary power outage time | Operation continues with an instantaneous blackout of 5 ms or less. |
| Frequency | 57 to 150 Hz : Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2 |
| Direct installation frequency | 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2 |
| Anti-vibration when DIN rail is installed frequency | 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2 |
| 1 phase 1 count input | [C235, C236] Up to 2 points: Up to 60 kHz High speed comparison When using SET / RESET: 30 kHz [C237 to C245] Up to 4 points: Up to 10 kHz High speed comparison When using SET / RESET: 10 kHz Processed by high- The sum of the frequencies to be summed (2-phase counter adds twice the input frequency), the maximum is 60 kHz. High Speed ??Comparison When using SET / RESET, 30 kHz is the maximum for the sum of the frequencies processed by the sequencer with the high-speed counter and pulse density instruction (2-phase counter adds twice the input frequency). |
| 1 phase 2 count input | [C246] Maximum 1 point: Up to 60 kHz High speed comparison When using SET / RESET: 30 kHz [C247 to C250] Up to 2 points: Up to 10 kHz High speed comparison When using SET / RESET: 10 kHz Frequency processed by the sequencer with high- (2-phase counter adds twice the input frequency), the maximum is 60 kHz. High Speed ??Comparison When using SET / RESET, 30 kHz is the maximum for the sum of the frequencies processed by the sequencer with the high-speed counter and pulse density instruction (2-phase counter adds twice the input frequency). |
| 2 phase 2 count input | [C251] Maximum 1 point: Up to 30 kHz High speed comparison When using SET / RESET: 15 kHz [C252 to C255] Up to 2 points: Up to 5 kHz High speed comparison When using SET / RESET: 5 kHz Frequency processed by the sequencer with high- (2-phase counter adds twice the input frequency), the maximum is 60 kHz. High Speed ??Comparison When using SET / RESET, 30 kHz is the maximum for the sum of the frequencies processed by the sequencer with the high-speed counter and pulse density instruction (2-phase counter adds twice the input frequency). |
| Input connection shape | Removable terminal block (M3 screw) |
| Output connection shape | Terminal block (M3 screw) |
| Input response time | Approximately 10 ms X000 to X007 have a built-in digital filter and can be changed in 1 ms increments to 0 to 15 ms by D8020. When 0 is specified, X000, X001 is 10 μs, and X002 to X007 is 50 μs. |
| Response time OFF → ON | About 10 ms |
| Operating temperature | 0 to 55 ° C. ... Operating, -20 to 70 ° C....when saved |
| Use altitude | It can not be used under an environment pressurized to 2,000 m or less under atmospheric pressure. It may break down. |
| Relative humidity | 35 to 85% RH (noncondensing)...at operation |
| Shipping weight | 1.7 Kg |
| Other | Two internal analog volume can be used as analog timer VR 1: D 8030, VR 2: D 8031 ??2 points (0 to 255) |
| Ground | Class D grounding (grounding resistance: 100 Ω or less)Grounding must be dedicated ground or common ground. |
| Nesting | [For master control] N 0 to N 7 8 points (for MC command) |
| ON → OFF | About 10 ms |
| Total score | 128 points or less (when adding together) |
| Input format | sink |
| Manufacturer | Mitsubishi Electric |
| Minimum load | DC 5 V 2 mA (reference value) |
| Output relay | Y000 to Y177 128 points (octal number) When added and used |
| X010 or later | 3.5 mA or more |
| Inductive load | 80VA |
| Noise immunity | Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si |
| Use atmosphere | There is no corrosive property, flammable gas, conductive dust (dust) is not serious |
| Hexadecimal | 16 bits: 0 to FFFF 32 bits: 0 to FFFFFFFF |
| Input interrupt | I00□ ~ I50□ 6 points |
| Special purpose | M8000 to M8255 256 points |
| 32 bit up / down | C200 to C219 20 points (-2, 147, 483, 648 to +2, 147, 483, 647 counts) |
| For 16 bit index | V 0 to V 7, Z 0 to Z 7 16 points |
| Counter 16 bit up | C 0 to C 15 16 points (0 to 32,767 counts) |
| Impact resistance | 147 m / s 2 , working time 11 ms, criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2 |
| 16 bit special use | D 8000 to D 8255 256 points |
| Circuit insulation | Mechanical insulation |
| High speed counter | [32-bit high-speed up / down (EEPROM Keep)] C235 ~ C255 1 phase: 60 kHz, 10 kHz 2 phase: 30 kHz, 5 kHz there is a limit to the number and input frequency that can be used according to the conditions used. ※ Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes. |
| Keep (EEPROM keep) | S10 to S127 118 points ※ Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes. |
| Estimated lead time | Usually ships in 1 - 10 working days. |
| Input signal format | No-voltage contact input NPN open collector transistor |
| Protection function | With password protection function (by keyword function) |
| File register | D1000 to D7999 Up to 7000 points (It can be set to program area (EEPROM) as file register in units of 500 points from D1000 according to parameters) |
| Programming language | Relay symbol method + step ladder method (SFC expressible) |
| Insulation resistance | When conducting the insulation resistance test, perform the following voltage between each terminal and the ground terminal of the basic unit. Between power supply terminal (DC power supply) and earth terminal: 500 VDC DC insulation resistance meter 5 MΩ or more Output terminal (relay) and earth terminal: 500 VDC with insulation resistance meter 5 MΩ or more |
| Keep (capacitor keep) | S128 to S999 872 points ※ Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving. |
| Number of input points | 24 points |
| 16 bit up (EEPROM keep) | C16 to C31 16 points (0 to 32,767 counts) * Note on keep area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes. |
| Application instruction | 3.7 to several 100 μs / instructions |
| Input operation display | LED ON when input is ON |
| Number of output points | 16 points |
| Timer (on-delay) 100 | T0 to T199 200 points (0.1 to 3,276.7 seconds) |
| Input circuit insulation | Photocoupler insulation |
| Arithmetic control method | Stored program iterative calculation method with interrupt instruction |
| Write function during RUN | Yes (program changeable during sequencer RUN) |
| 16 bit up (Capacitor keep) | C32 to C199 168 points (0 to 32,767 counts) * Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving. |
| Maximum load resistive load | 2A or less / per output 8 A or less / per COM terminal |
| Output operation indication | LED lit when relay coil is energized |
| Constant decimal number | 16 bits: -32,768 to + 32,767 32 bits: -2, 147, 483, 648 to +2, 147, 483, 647 |
| Input impedance x000 to x007 | 3.3 kΩ |
| For 16-bit keep (EEPROM keep) | D128 to D255 128 points ※ Note on the keep area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes. |
| Input (output control method) | Batch processing method (when END instruction is executed), I / O refresh command, with pulse catch function |
| Pointer JUMP, for CALL branch | P0 to P127 128 points (for CJ instruction, CALL instruction, P63 for END jump) |
| Memory cassette (memory board) | FX1N-EEPROM-8L (8000 step EEPROM) |
| Real time clock clock function | Built-in 1980 to 2079 (with leap year correction) 2-digit / 4-digit year AD changeable, monthly difference ± 45 seconds (25 ° C) ※ Note on clock function The current time of the built- It is backed up with. The large capacity condenser (built-in) is fully charged at the energization time of 30 minutes and holds the present value for 10 days. Also, you can hold it with a battery by using an optional battery. |
| Device i (O relay input relay) | X000 to X177 128 points (octal number) When added and used |
| Auxiliary relay for general use | M 0 to M 383 384 points |
| For 16-bit keep (capacitor keep) | D256 to D7999 7744 points ※ Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving. |
| 32 bit up / down (Capacitor keep) | C220 to C234 15 points (-2, 147, 483, 648 to +2, 147, 483, 647 counts) * Note on Keep Area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving. |
| Internal memory capacity (format) | 8000 steps EEPROM (memory backup not required) |
| State initial state (EEPROM keep) | S0 to S9 10 points ※ Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes. |
| Program memory maximum memory capacity | 8000 step comments, maximum 8000 steps including file register |
| Types of instructions basic instruction | . Sequence instruction: 27 pieces . Step ladder command: 2 pieces |
| Number of remote i (O points (CC - link)) | 128 points or less including real I / O |
| Arithmetic processing speed basic instruction | 0.55 to 0.7 μs / instructions |
| Number of input (output points number of input points) | 128 points or less (at the time of addition and extension use) However, the input / output total is 128 points or less |
| Data register (32 bits in pair use) for 16-bit general purpose | D0 to D127 128 points |
MPN