Mitsubishi Electric FX2N-2LC — PLCs (Programmable Logic Controllers)

Mitsubishi FX2N-2LC Temperature Adjustment Block, EOL

MPNFX2N-2LC
End of Life

Mitsubishi Electric FX2N-2LC temperature adjustment block, FX2N series, 2-loop PID controller, CT input, EOL (end-of-life).

$169.00Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

FX2N-2LC — Specifications
ParameterValue
Frequency57 to 150 HzAcceleration: 9.8 m / s 2 X, Y, Z each 10 times (total 80 minutes each)
Operation mode0Measured value monitor 1: Measured value monitor + temperature alarm 2: Measured value monitor + temperature alarm + control (selected by buffer memory)
Direct mountingFrequency10 to 57 HzSingle amplitude: 0.075 mm X, Y, Z each direction 10 times (total 80 minutes each)
Noise resistantNoise voltage1,000 Vp-p, noise width: 1 μs, rise time: 1 ns, period: 30 to 100 Hz noise simulator
memoryBuilt-in EEPROM (number of rewrites100,000 times)
groundType d grounding (Grounding resistance100 Ω or less) < Do not connect to a common ground with a high-power system> Connect a dedicated ground or shared ground.
Vibration resistanceWhen mounting DIN railFrequency10 to 57 HzSingle amplitude: 0.035 mm X, Y, Z each direction 10 times (total 80 minutes each)
Measurement accuracyambient temperature 23 ° c ± 5 °Input range ± 0.3% ± 1 digit Ambient temperature 0 ° C to 55 ° C: Input range ± 0.7% ± 1 digit However, B input 0 to 399 ° C (0 to 799 ° F) and PLII , 0 to 32 ° F of WRe5-26 input is out of guaranteed accuracy range
Withstand voltageBetween analog input terminal and ground terminalAC500V 1 minute
Insulation resistanceBetween analog input terminal and ground terminal5 MΩ or more with DC 500 V insulation resistance tester
Current detector (CT) input (heater current measurement value)When using CTL-120.0 to 100.0 A When using CTL-6: 0.0 to 30.0 A

Product details

Temperature adjustment block for FX2N racks

The FX2N-2LC is a dedicated temperature adjustment block that snaps onto a Mitsubishi FX2N PLC rack, adding two loops of PID temperature control without consuming the CPU's main scan cycle. Operation mode is selected via buffer memory: mode 0 is measured value monitor only, mode 1 adds a temperature alarm, and mode 2 adds full PID control — so the same block serves as a monitor-only card or a closed-loop controller depending on the application.

Measurement accuracy and sensor compatibility

Heater current is monitored via an external CT: with a CTL-12 the range is 0.0 to 100.0 A; with a CTL-6 it is 0.0 to 30.0 A — useful for detecting heater burnout in electric furnaces or extruder zones.

Environmental and electrical ratings

Vibration resistance follows IEC 61131-2: 57 to 150 Hz at 9.8 m/s² acceleration, and 10 to 57 Hz at 0.075 mm single amplitude, applied in each of X, Y, Z directions ten times (80 minutes total per axis). Noise immunity is tested to 1,000 Vp-p with 1 μs pulse width and 1 ns rise time, using a 30 to 100 Hz noise simulator. Grounding must be Type D (100 Ω or less) and dedicated — do not share a ground with high-power equipment. Withstand voltage between analog input and ground is AC 500 V for 1 minute; insulation resistance is 5 MΩ or more at DC 500 V.

Frequently asked questions

Where can I buy the FX2N-2LC and how do I get a price?

The FX2N-2LC is sourced through independent distribution channels.

What is the FX2N-2LC used for?

It is a temperature adjustment block for Mitsubishi FX2N PLCs, providing two loops of PID temperature control with selectable operating modes (monitor, alarm, or full control) and heater current monitoring via an external CT.