FX3U-64CCL - Mitsubishi Electric
MPNFX3U-64CCL
Programmable Controllers MELSEC
$191.00Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026
Specifications
| Parameter | Value |
|---|---|
| Station type | Intelligent device station |
| Withstand voltage | Between all terminals and ground terminal: 500 VAC for 1 minute |
| Current consumption | 220 mA |
| Power supply | DC 5 V internal power supply: DC 5 V of the programmable controller is not used. (DC 5 V is converted from 24 VDC external power supply) |
| 24 VDC external power supply | Power is supplied from the external terminal block. (+ 20% - 15% ripple (pp) within 5%) |
| Allowable momentary power outage time | PS 1: Continue operation against momentary power failure of 1 ms or less |
| Frequency | 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total) |
| Direct installation frequency | 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) |
| Anti-vibration when DIN rail is installed frequency | 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) |
| Communication method | Broadcast polling method |
| Connection cable | CC-Link dedicated cable, CC-Link exclusive high-performance cable, Ver. 1.10 compatible CC-Link dedicated cable |
| Maximum cable total extension (maximum transmission distance) | According to CC-Link specification. |
All specifications+28 ▾
| Parameter | Value |
|---|---|
| Operating temperature | 0 to 55 ° C. ··· Operating -25 to 75 ° C. ····· Save |
| Use altitude | Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down. |
| Relative humidity | 5 to 95% RH (noncondensing) · · · · in operation |
| Shipping weight | 2 kg |
| Mass | 0.3 kg |
| Ground | Class D grounding (grounding resistance: 100 O or less) <Common grounding with high voltage system is not allowed> |
| Manufacturer | Mitsubishi Electric |
| Coding scheme | NRZI system |
| Display | RD, SD, RUN, ERR., L RUN, L ERR., POWER |
| Noise immunity | Noise voltage with 1,000 Vp-p, noise width 1 µs, rising 1 ns, with noise simulator with period of 30 to 100 Hz |
| Station number | 1 to 64 stations (set with rotary switch) |
| Use atmosphere | There is no corrosive property, flammable gas, conductive dust (dust) is not serious |
| CC-Link version | Ver.2.00 (Ver.1.10 is also supported) |
| Impact resistance | 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse |
| Insulation method | The network bus and the internal power supply are photocoupler isolated |
| Transmission speed | 156 Kbps / 625 Kbps / 2.5 Mbps / 5 Mbps / 10 Mbps |
| Estimated lead time | 1 - 10 Working Days |
| Transmission format | HDLC compliant |
| Error control method | CRC (X 16 + X 12 + X 5 + 1) |
| Application sequencer | FX5U, FX5UC, FX3G, FX3U, FX3GC, FX3UC (Ver. 2.20 SER No.55 **** after May 2005 product) |
| Insulation resistance | Between all terminals and ground terminal: 500 MV DC 500 MO or more with an insulation resistance meter |
| Synchronization method | Flag synchronization method |
| Transmission path format | Bus (RS-485) |
| Number of occupied stations | 1 to 4 stations (set with rotary switch) |
| Remote register point number | The number of remote registers per station is 4 RW write areas, 4 RW read areas. (There are 1 to 8 times setting depending on extended cyclic setting) |
| Number of remote i (O points) | The number of remote I / O points per station is 32 input points and 32 output points. (There is set by the extended cyclic setting of 1 to 8 times) |
| Communicate with the sequencer | Perform through the buffer memory with the FROM / TO instruction (or directly designate the buffer memory) |
| Number of occupied i (O points) | 8 points (It can count either input or output) |