Skip to main content
Mitsubishi Electric FX5-4AD-PT-ADP — PLCs (Programmable Logic Controllers)

Mitsubishi FX5-4AD-PT-ADP PT100/1000 Input, 0.1°C Resolution

MPNFX5-4AD-PT-ADP

Mitsubishi Electric FX5-4AD-PT-ADP analog input module, PT100/1000 temperature sensor, 4 channels, 0.1°C resolution, -200 to +850°C range, 0.153 kg.

$323.00 – $482.47Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

FX5-4AD-PT-ADP — Mechanical
ParameterValue
Weight0.153 Kg
FX5-4AD-PT-ADP — Other specifications
ParameterValue
Resolution0.1°C
Product typeProgrammable Logic Controller
Conversion speedApprox. 85 ms/channel*2
Isolation methodBetween input terminal and CPU module: Photocoupler, Between input channels: Non-isolation
Temperature measuring range-200 to +850°C
Number of analog input points4 points (4 channels)
Number of occupied i (O points)0 point (This number is not related to the maximum number of I/O points of the PLC.)

Product details

PT100/1000 input module for the FX5 rack

The FX5-4AD-PT-ADP is a 4-channel analog input module that reads PT100 or PT1000 RTD temperature sensors directly, resolving to 0.1°C across a -200 to +850°C span. Each channel converts at approximately 85 ms, which sets the practical scan-rate ceiling for a multi-channel temperature loop — if you need faster updates per point, budget for a separate module per sensor or accept the aggregate update time. The module occupies zero I/O points on the FX5 backplane, so it does not eat into the CPU's maximum I/O count — useful when the rack is already dense.

Isolation and wiring considerations

Photocoupler isolation sits between the input terminals and the CPU module, but there is no channel-to-channel isolation — adjacent input channels share a common reference. For cold-storage or freezer applications where sensor runs cross different grounding potentials, the non-isolated channel architecture means you keep the PT100/1000 returns on a common rail and verify the ground loop is not driving offset error at 0.1°C resolution.

Frequently asked questions

What is the difference between FX5-4AD-PT-ADP and FX5-4AD-TC-ADP?

The FX5-4AD-PT-ADP reads PT100/1000 RTD sensors, while the FX5-4AD-TC-ADP reads thermocouple types K, J, T, B, R, and S. Both are 4-channel modules with the same conversion speed and isolation architecture, so they swap into the same rack slot without rewiring the backplane.

What is the conversion speed per channel on the FX5-4AD-PT-ADP?

Each channel converts at approximately 85 ms, which means a full four-channel scan takes about 340 ms before the data is updated in the buffer.

MPN
FX5-4AD-PT-ADP