Mitsubishi QD75P2 is a two-axis positioning module for the Q-series PLC — parameters, positioning data, and block start data live on flash ROM, so no battery keeps the setup after a power cycle. Control modes cover PTP (incremental or absolute system), linear and 2-axis circular interpolation, speed control, and speed-position switching. Pulse output tops at 200 kpps. The module consumes 32 I/O points in the backplane and draws 0.46 A at 5 VDC. Connectors (A6CON1, A6CON2, A6CON4) are sold separately; recommended wire is 0.3 mm² or AWG #24.

Mitsubishi QD75P2 2-Axis Position Module, 200kpps
MPNQD75P2
Mitsubishi Q series QD75P2 two-axis positioning module, 200kpps max output, flash ROM backup, 32 I/O points.
$741.00 – $775.97Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jun 2026
Specifications
| Parameter | Value |
|---|---|
| Internal current consumption(5VDC) | QD75P2 : 0.46A,QD75D2 : 0.56A |
| Applicable wire size | 0.3 mm2 (for A6CON1 or A6CON4), AWG #24 (for A6CON2)Applicable connector for external device: A6CON1, A6CON2, A6CON4 (sold separately) |
| Shipping weight | 1 Kg |
| Backup | Parameters, positioning data, and block start data can be saved on flash ROM (battery-less backup) |
| PTP control | Incremental system/absolute system |
| Control unit | mm, inch, degree, pulse |
| Path control | Incremental system/absolute system |
| Control system | PTP (Point To Point) control, path control (both linear and arc can be set), speed control, speedposition |
| Positioning data | 600 data (positioning data Nos. 1 to 600)/axis,(Can be set with peripheral device or sequence program.) |
| Positioning range | -In absolute system• –214748364.8 to 214748364.7 (?m)• –21474.83648 to 21474.83647 (inch)• 0 to 359.99999 (degree)• –2147483648 to 2147483647 (pulse)In incremental system• –214748364.8 to 214748364.7 (?m)• –21474.83648 to 21474.83647 (inch)• –21474.83648 to 21474.83647 (degree)• –2147483648 to 2147483647 (pulse)In speed-position switching control (INC mode) / position-speed switching control• 0 to 214748364.7 (?m)• 0 to 21474.83647 (inch)• 0 to 21474.83647 (degree)• 0 to 2147483647 (pulse)In speed-position switching control (ABS mode)• 0 to 359.99999 (degree) |
| No. of control axes | 2 axes |
| Interpolation function | 2-axis linear interpolation,2-axis circular interpolation |
All specifications+7 ▾
| Parameter | Value |
|---|---|
| No. of occupied i (O points) | 32 points (I/O assignment: 32 points for intelligent function module)Flash ROM write count: Max. 100000 timesInternal current consumption (5VDC): QD75P2 : 0.46A, QD75D2 : 0.56A |
| Sudden stop deceleration time | 1 to 8388608 (ms) |
| Acceleration (deceleration time) | 1 to 8388608 (ms),Four patterns can be set for each of acceleration time and deceleration time |
| Position-speed switching control | Incremental system |
| Speed-position switching control | Incremental system/absolute system 2 |
| Acceleration (deceleration process) | Automatic trapezoidal acceleration/deceleration, S-pattern acceleration/deceleration |
| Max. output pulseQD75P1, QD75P2, QD75P4 | 200kppsQD75D1, QD75D2, QD75D4 : 1Mpps |
Product details
Frequently asked questions
Does the QD75P2 store positioning data without a battery?
Yes — parameters, positioning data, and block start data are saved on flash ROM, so no battery backup is needed.
What PTP control modes does the QD75P2 support?
The module supports both incremental and absolute systems for PTP control.
MPN