Omron 61F-1P-AC220 — General Purpose Relays

Omron 61F-1P-AC220 Level Controller, 220VAC, High/Low Level

MPN61F-1P-AC220
Active

Omron 61F series, High/Low Level controller, 61F-1P-AC220, 220VAC supply, SPDT (2 Form C) relay outputs, 0~4kOhm sensitivity, 5A @ 200VAC contact rating, socketable.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-1P-AC220 — Identification
ParameterValue
Series61F
61F-1P-AC220 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage5A @ 200VAC
61F-1P-AC220 — Coil & Supply
ParameterValue
Supply voltage range220VAC
61F-1P-AC220 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-1P-AC220 — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 15 Pin (Octal)
61F-1P-AC220 — Environmental
ParameterValue
Operating temperature range-10°C~55°C
61F-1P-AC220 — Other specifications
ParameterValue
Weight1.1 lbs (499 g)
FeaturesAlarm High/Low - Contact, Level Indication
Output signalRelay (2)
Sensitivity0 ~ 4kOhm
Distance - control to sensor1km

Product details

The Omron 61F-1P-AC220 is a High/Low Level controller from the 61F series, designed for conductive liquid level detection in tanks, reservoirs, and process vessels. It operates on a 220VAC supply and provides two SPDT (2 Form C) relay outputs rated at 5A @ 200VAC for alarm and control functions. Sensitivity is adjustable from 0 to 4kOhm, which covers most conductive liquids including water, weak acids, and alkalis. The control-to-sensor distance can reach up to 1km, making it suitable for remote tank farms or distributed monitoring points where the controller sits in a central panel and the probes are at the vessel.

Integration Notes

Socketable mounting via a 15-pin octal plug base. The base stays in the panel for wiring. For outdoor or unheated installations, verify the ambient stays above the low end.

The 5A @ 200VAC contact rating applies to the relay outputs; for 220VAC line voltage, derate slightly per Omron's contact-life curve. Use the contacts for pilot duty (contactors, solenoid valves, alarms) rather than direct motor switching. Sensitivity range of 0-4kOhm means the controller triggers when resistance falls below the setpoint. Set the dial for reliable detection.

Frequently asked questions

What is the 61F-1P-AC220's listed type?

The 61F-1P-AC220 is listed as a High/Low Level controller, meaning it provides both high-level and low-level alarm or control outputs from a single unit.

What is the 61F-1P-AC220's sensitivity range?

Sensitivity is adjustable from 0 to 4kOhm, covering most conductive liquids including water, weak acids, and alkalis.

What is the maximum distance between the controller and the sensor probes?

The control-to-sensor distance can reach up to 1km, suitable for remote tank farms or distributed monitoring points.