Skip to main content
Omron 61F-G1H AC110/220 — General Purpose Relays

Omron 61F-G1H AC110/220 Level Controller, 110/220VAC

MPN61F-G1H AC110/220
Active

Omron 61F series, High/Low Level controller, 61F-G1H AC110/220, 110/220VAC supply, relay (2) output, SPDT (2 Form C), sensitivity 15kOhm ~ 70kOhm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-G1H AC110/220 — Identification
ParameterValue
Series61F
61F-G1H AC110/220 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage5A @ 220VAC
61F-G1H AC110/220 — Coil & Supply
ParameterValue
Supply voltage range110/220VAC
61F-G1H AC110/220 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-G1H AC110/220 — Mechanical
ParameterValue
Mounting typeChassis Mount
Termination styleScrew Terminal
61F-G1H AC110/220 — Environmental
ParameterValue
Operating temperature range-10°C~55°C
61F-G1H AC110/220 — Other specifications
ParameterValue
Weight1.7 lbs (771.1 g)
FeaturesAlarm Low - Contact, Idling Prevention
Output signalRelay (2)
Sensitivity15kOhm ~ 70kOhm
Distance - control to sensor50m

Product details

The Omron 61F-G1H AC110/220 is a High/Low Level liquid level controller from the 61F series, running on a dual-rated 110/220VAC supply. This is the chassis-mount version with screw terminals — no DIN-rail adapter, so plan for a panel backplate or enclosure floor mount. Two SPDT (2 Form C) relay outputs rated 5A @ 220VAC handle the pump-up/pump-down or alarm logic; the sensitivity adjustment spans 15kOhm to 70kOhm, which covers most conductive liquids from tap water to weak chemical solutions.

The 50m maximum distance between controller and sensor probe means the 61F-G1H can sit in a central panel while the probes are out on a tank farm or sump pit — no need to locate the controller at the vessel. The sensitivity range (15kOhm to 70kOhm) is the resistance threshold at which the relay trips; lower-resistance liquids (tap water ~10kOhm) need the low end of the range, while higher-resistance liquids (distilled water or dilute chemicals) need the upper end. If your liquid is outside that band, the controller won't detect level changes reliably.

Frequently asked questions

What is the supply voltage for this level controller?

The 61F-G1H AC110/220 accepts a dual-rated 110/220VAC supply, so it works on either 110V or 220V line voltage without rewiring.

What is the maximum distance between the controller and the sensor probes?

The maximum control-to-sensor distance is 50m, allowing the controller to be panel-mounted while the probes are at a remote tank or sump.

Where can I buy the 61F-G1H AC110/220?

The 61F-G1H AC110/220 is sourced and quoted to order against an RFQ through independent distribution, with availability and current pricing confirmed at quote time.

MPN