Skip to main content
Omron 61F-G1ND AC110/120 — General Purpose Relays

Omron 61F-G1ND AC110/120 Level Controller, High/Low Type, 11

MPN61F-G1ND AC110/120
Active

Omron 61F series, High/Low Level Controller, 61F-G1ND AC110/120, 110/120VAC supply, SPDT (2 Form C) relay output, 3A @ 200VAC, DIN rail mount, screw terminal.

$434.27 – $447.64Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-G1ND AC110/120 — Identification
ParameterValue
Series61F
61F-G1ND AC110/120 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 200VAC
61F-G1ND AC110/120 — Coil & Supply
ParameterValue
Supply voltage range110/120VAC
61F-G1ND AC110/120 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-G1ND AC110/120 — Mechanical
ParameterValue
Mounting typeDIN Rail
Termination styleScrew Terminal
61F-G1ND AC110/120 — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-G1ND AC110/120 — Other specifications
ParameterValue
Weight0.904 lb (410.05 g)
FeaturesAlarm Low - Contact, Idling Prevention
Output signalRelay (2)
Sensitivity0 ~ 1.8kOhm
Distance - control to sensor1km

Product details

The Omron 61F-G1ND AC110/120 is a High/Low level controller from the 61F series, designed for conductive liquid level detection in tanks, reservoirs, and process vessels. It operates on a 110/120VAC supply and provides two SPDT (2 Form C) relay outputs rated at 3A @ 200VAC, giving you independent control for high and low alarm or pump start/stop logic. Sensitivity is adjustable from 0 to 1.8 kΩ, which means it can detect liquids with varying conductivity — from relatively pure water to more conductive process fluids — without false triggering on foam or residue. The control-to-sensor distance extends up to 1 km, so the controller can sit in a central panel while the probe is out at the tank. Mounts on standard DIN rail with screw-terminal wiring, making it a straightforward swap into an existing panel without re-terminating the field wiring.

The 3A @ 200VAC contact rating on the SPDT relays governs the load it can switch directly — small pumps, solenoid valves, or pilot relays. For larger motor loads, use the relay to drive an external contactor. The 1 km sensor distance is the maximum cable run between controller and probe; for runs over a few hundred meters, account for voltage drop in the sense wire, especially with lower-conductivity fluids. The Alarm Low - Contact and Idling Prevention features mean the controller can signal a low-level condition and prevent the pump from running dry — a common failure mode in sump and condensate applications.

Frequently asked questions

What is the 61F-G1ND AC110/120 used for?

It is a conductive liquid level controller that detects high and low levels in tanks, sumps, or reservoirs, typically used to start/stop pumps or trigger alarms based on liquid presence.

What does the sensitivity range of 0 to 1.8 kΩ mean?

It means the controller can be adjusted to detect liquids with electrical resistance in that range — from relatively pure water (higher resistance) to conductive process fluids (lower resistance) — without nuisance tripping on foam or residue buildup.

MPN
61F-G1ND AC110/120