Omron 61F series, High/Low Level Controller, 110/220VAC supply, SPDT (2 Form C) relay outputs, 0~1.8kOhm sensitivity, DIN rail mount, 2km control-to-sensor distance.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-G1NL AC110/220 2KM — Identification
ParameterValue
Series61F
61F-G1NL AC110/220 2KM — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 200VAC
61F-G1NL AC110/220 2KM — Coil & Supply
ParameterValue
Supply voltage range110/220VAC
61F-G1NL AC110/220 2KM — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-G1NL AC110/220 2KM — Mechanical
ParameterValue
Mounting typeDIN Rail
Termination styleScrew Terminal
61F-G1NL AC110/220 2KM — Environmental
ParameterValue
Operating temperature range-10°C~55°C
61F-G1NL AC110/220 2KM — Other specifications
ParameterValue
Weight0.904 lb (410.05 g)
FeaturesAlarm Low - Contact, Idling Prevention
Output signalRelay (2)
Sensitivity0 ~ 1.8kOhm
Distance - control to sensor2km

Product details

The Omron 61F-G1NL AC110/220 2KM is a high/low level controller from the 61F series, designed to monitor liquid levels and switch relay outputs based on probe resistance. It accepts a dual-rated 110/220VAC supply, so the same unit works on either line voltage without a jumper change — useful when the panel supply is still being finalized. Two SPDT (2 Form C) relay outputs rated 3A @ 200VAC handle the alarm and pump control logic. The sensitivity adjustment spans 0 to 1.8 kOhm, letting you tune the trip point for conductive liquids with different resistivity — from tap water to mildly conductive process fluids. The headline spec is the 2 km control-to-sensor distance. That means the controller can sit in a central panel while the probe is at a remote tank or sump, as long as the wiring resistance stays under the sensitivity range. For a long cable run, keep the pair twisted and away from power conductors to avoid false trips.

DIN rail mount with screw terminals — standard panel integration. Features include Alarm Low - Contact and Idling Prevention. The idling prevention logic stops the pump from short-cycling when the level is at the boundary — a common failure point in sump and lift-station controls.

Frequently asked questions

What is the supply voltage for this level controller?

It accepts 110/220VAC — dual-rated, so the same unit works on either line voltage without a jumper change.

How do I get current pricing and availability for 61F-G1NL AC110/220 2KM?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

MPN
61F-G1NL AC110/220 2KM