Omron 61F-G1NR AC110/220 — General Purpose Relays

Omron 61F-G1NR AC110/220 Level Controller, High/Low, 110/220

MPN61F-G1NR AC110/220
Active

Omron 61F series High/Low Level Controller, 61F-G1NR AC110/220, 110/220VAC supply, SPDT relay output, DIN rail mount.

$434.27 – $447.64Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-G1NR AC110/220 — Identification
ParameterValue
Series61F
61F-G1NR AC110/220 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 200VAC
61F-G1NR AC110/220 — Coil & Supply
ParameterValue
Supply voltage range110/220VAC
61F-G1NR AC110/220 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-G1NR AC110/220 — Mechanical
ParameterValue
Mounting typeDIN Rail
Termination styleScrew Terminal
61F-G1NR AC110/220 — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-G1NR AC110/220 — Other specifications
ParameterValue
Weight0.904 lb (410.05 g)
FeaturesAlarm Low - Contact, Idling Prevention, Two Wire/Three Probe
Output signalRelay (2)
Sensitivity0 ~ 1.1kOhm
Distance - control to sensor800m

Product details

The Omron 61F-G1NR AC110/220 is a High/Low level controller from the 61F series, designed for liquid-level monitoring in tanks, reservoirs, and process vessels. It operates on a 110/220VAC supply and uses a two-wire or three-probe sensing method with a sensitivity range of 0 to 1.1kOhm — adjustable to match the conductivity of the liquid. The relay output (2x SPDT Form C) is rated 3A at 200VAC, enough to drive a pump contactor or alarm directly. Mounts on standard DIN rail (snap-on) with screw terminals for field wiring. The control-to-sensor distance can reach 800m, so the controller can sit in a central panel while the probes are out at the tank. Built-in features include Alarm Low contact and idling prevention — the latter keeps the pump from cycling on foam or turbulence.

The 0–1.1kOhm sensitivity covers most conductive liquids — water with typical tap conductivity (500–800 µS/cm) is well within range, but deionized water or low-conductivity hydrocarbons may need a different controller. The 800m cable distance is the maximum between controller and probe; voltage drop over that length at the probe's sensing current is negligible with the recommended cable gauge. The 3A contact rating at 200VAC is sufficient for direct control of a small pump contactor (e.g., up to 0.75 kW) or pilot relay. For larger loads, interpose a contactor. The SPDT (Form C) per channel gives both fill and empty logic without an external inverter.

DIN-rail snap-on mounting with screw terminals means a 5-minute swap on a live panel if you pre-wire a removable terminal block.

Frequently asked questions

How do I get pricing and availability for 61F-G1NR AC110/220?

Pricing and stock are confirmed at quote time against an RFQ. Submit a request through the storefront; availability and current market pricing are provided on inquiry.

What does the High/Low Level type mean?

High/Low Level means the controller can detect both high and low liquid levels independently, using two separate probes (or one common and two sense probes). This allows automatic fill/empty cycling without a separate timer or PLC.

What is the maximum distance between the controller and the sensor probes?

The maximum control-to-sensor distance is 800 meters. This allows the controller to be mounted in a central panel while the probes are at a remote tank or sump.