Skip to main content
Omron 61F-G1P 220AC — General Purpose Relays

Omron 61F-G1P 220AC Liquid Level Controller, 220VAC, SPDT

MPN61F-G1P 220AC
Active

Omron 61F series, High/Low Level liquid level controller, 220VAC supply, SPDT relay output, 0-4kOhm sensitivity, 1km max sensor distance, socketable octal plug.

$381.78 – $393.23Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-G1P 220AC — Identification
ParameterValue
Series61F
61F-G1P 220AC — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage5A @ 200VAC
61F-G1P 220AC — Coil & Supply
ParameterValue
Supply voltage range220VAC
61F-G1P 220AC — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-G1P 220AC — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 15 Pin (Octal)
61F-G1P 220AC — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-G1P 220AC — Other specifications
ParameterValue
Weight1.1 lbs (499 g)
FeaturesAlarm Low - Contact, Idling Prevention
Output signalRelay
Sensitivity0 ~ 4kOhm
Distance - control to sensor1km

Product details

The Omron 61F-G1P 220AC is a high/low level liquid level controller from the 61F series, designed to detect and control liquid levels in tanks, reservoirs, and process vessels using conductive probes. It operates on a 220VAC supply and outputs through a SPDT relay (2 Form C) rated at 5A @ 200VAC. The sensitivity adjustment covers 0 to 4kOhm, letting you tune the detection threshold for different liquid conductivities — from relatively pure water to conductive process fluids. The control-to-sensor distance can reach up to 1km, which suits remote tank farms or large industrial sites where the controller panel sits far from the vessel. Built-in features include alarm-low contact output and idling prevention logic, which helps avoid pump dry-running or overflow conditions without needing an external timer or auxiliary relay.

The unit mounts via a socketable octal base — 15-pin plug-in termination. That means you wire the socket once, then the controller module plugs in for quick replacement without disturbing the panel wiring. Standard for panel builders who want field-swappable level controls.

Frequently asked questions

What is the sensitivity range of 61F-G1P 220AC?

The sensitivity is adjustable from 0 to 4kOhm, allowing the controller to work with different liquid conductivities.

What is the maximum distance between the controller and the sensor probes?

The maximum control-to-sensor distance is 1km, suitable for remote tank monitoring.

MPN
61F-G1P 220AC