Skip to main content
Omron 61F-G2ND AC110/220 — Process / Temperature Controllers

Omron 61F-G2ND AC110/220 Level Controller, 110/220VAC, DIN R

MPN61F-G2ND AC110/220
Active

Omron 61F series, High/Low Level controller, 61F-G2ND AC110/220, 110/220VAC supply, relay (2) output, SPDT contacts, 0~1.8kOhm sensitivity, DIN rail mount.

$434.27 – $447.64Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-G2ND AC110/220 — Identification
ParameterValue
Series61F
TypeHigh/Low Level
61F-G2ND AC110/220 — Electrical
ParameterValue
Supply voltage110/220VAC
61F-G2ND AC110/220 — I/O
ParameterValue
Output typeRelay (2)
61F-G2ND AC110/220 — Performance
ParameterValue
FeaturesAlarm High - Contact
61F-G2ND AC110/220 — Environmental
ParameterValue
Operating temperature-10°C ~ 55°C
61F-G2ND AC110/220 — Mechanical
ParameterValue
Mounting typeDIN Rail
Termination styleScrew Terminal
61F-G2ND AC110/220 — Other specifications
ParameterValue
Weight0.904 lb (410.05 g)
Sensitivity0 ~ 1.8kOhm
Contact formSPDT (1 Form C), SPDT (2 Form C)
Contact rating @ voltage3A @ 200VAC
Distance - control to sensor1km

Product details

Level controller for conductive liquids

The Omron 61F-G2ND AC110/220 is a High/Low Level controller from the 61F series, designed for conductive liquid level detection in tanks, reservoirs, and process vessels. It operates on a 110/220VAC supply and uses relay outputs (two relays) to signal alarm or control fill/drain cycles. The sensitivity range of 0 ~ 1.8kOhm means it can detect liquids with varying conductivity — from relatively pure water down to more conductive process fluids — by adjusting the threshold via the front-panel trimmer. The 1km maximum distance between controller and sensor electrodes gives flexibility for remote tank farms or elevated vessels where the electronics need to be away from the wet area.

Contact ratings and wiring

Each SPDT relay is rated 3A @ 200VAC, adequate for pilot duty on contactors, solenoid valves, or alarm panels. Two Form C contacts (SPDT each) give independent N.O. and N.C. poles — one set can drive a pump-up circuit, the other a high-level alarm, without external interposing relays.

Frequently asked questions

What is the sensitivity range of 61F-G2ND AC110/220?

The sensitivity is adjustable from 0 to 1.8kOhm, covering most conductive liquids from tap water to process chemicals. Adjust the trimmer on the front face to match the electrode gap and liquid conductivity.

What is the maximum distance between the controller and the sensor electrodes?

The 61F-G2ND AC110/220 can drive sensor electrodes up to 1km away from the controller body, using the correct cable gauge per the wiring instructions.

Where can I buy 61F-G2ND AC110/220?

This part is sourced to order through independent industrial automation distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

MPN
61F-G2ND AC110/220