Skip to main content
Omron 61F-G3N AC100/200 — General Purpose Relays

Omron 61F-G3N AC100/200 Level Controller, 100/200VAC, SPDT

MPN61F-G3N AC100/200
Active

Omron 61F series High/Low Level Controller, 61F-G3N AC100/200, 100/200VAC supply, SPDT (2 Form C) relay outputs, 0 ~ 4kOhm sensitivity, DIN rail mount, screw terminal.

$467.68 – $1,012.89Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

61F-G3N AC100/200 — Identification
ParameterValue
Series61F
61F-G3N AC100/200 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 200VAC
61F-G3N AC100/200 — Coil & Supply
ParameterValue
Supply voltage range100/200VAC
61F-G3N AC100/200 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-G3N AC100/200 — Mechanical
ParameterValue
Mounting typeDIN Rail
Termination styleScrew Terminal
61F-G3N AC100/200 — Environmental
ParameterValue
Operating temperature range-10°C~55°C
61F-G3N AC100/200 — Other specifications
ParameterValue
Weight1.4 lbs (635 g)
FeaturesAlarm High - Contact
Output signalRelay (3)
Sensitivity0 ~ 4kOhm
Distance - control to sensor1km

Product details

The Omron 61F-G3N AC100/200 is a conductive liquid level controller from the 61F series, designed for high/low level detection in tanks, sumps, and process vessels. It operates on a 100/200VAC supply and provides three relay outputs (SPDT, 2 Form C) rated at 3A @ 200VAC. The sensitivity is adjustable from 0 to 4kΩ, which lets it work with different liquid conductivities — from clean water to mildly conductive process fluids. The control-to-sensor distance can run up to 1 km, so the controller can sit in a central panel while the electrodes are out on the tank.

The 0 ~ 4kΩ sensitivity range is the critical spec for the application engineer: it determines whether the controller can detect the liquid level reliably. Low-resistance liquids (tap water, many coolants) are easy; high-resistance liquids (deionized water, some chemicals) may need the sensitivity turned up or a different probe. The 1 km maximum distance between controller and sensor means the 61F-G3N can drive long cable runs without false triggering — useful for large tank farms or remote sumps. The SPDT (2 Form C) relay outputs give you one normally-open and one normally-closed contact per relay, which is enough to drive a fill valve and a high-level alarm, or a pump and a low-level alarm, without adding interposing relays. The 3A @ 200VAC contact rating handles small contactors and pilot lights directly; for larger loads, use the relay to switch a contactor coil.

Wire the supply and electrodes to the screw terminals and set the sensitivity pot.

Frequently asked questions

What is the maximum distance between the controller and the sensor electrodes?

The maximum control-to-sensor distance is 1 km, which allows the controller to be mounted in a central panel while the electrodes are located at a remote tank or sump.

MPN