The Omron 61F-G3NR AC110/220 is a conductive level controller from the 61F series, designed for High/Low Level detection in tanks and reservoirs. It operates on a dual-rated 110/220VAC supply, making it usable across both 110 V and 220 V line voltages without a separate transformer tap. Three relay outputs (SPDT, 2 Form C) rated 3A @ 200VAC drive alarms or pump contactors directly. The sensitivity adjustment from 0 to 1.1 kOhm lets you tune the probe circuit for water, wastewater, or conductive process fluids — higher resistance settings handle distilled or low-conductivity liquids. Control-to-sensor distance reaches 800 m, so the controller can sit in a panel remote from the tank. Screw terminals and DIN-rail mounting simplify panel integration — no special bracket or enclosure cutout needed.

Omron 61F-G3NR AC110/220 Level Controller, 110/220VAC DIN Ra
MPN61F-G3NR AC110/220
Active
Omron 61F series, High/Low Level controller, 61F-G3NR AC110/220, 110/220VAC supply, SPDT relay output, DIN rail mount.
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026
Specifications
Identification
| Parameter | Value |
|---|---|
| Series | 61F |
Contacts & Switching
| Parameter | Value |
|---|---|
| Contact form | SPDT (2 Form C) |
| Contact rating at voltage | 3A @ 200VAC |
Coil & Supply
| Parameter | Value |
|---|---|
| Supply voltage range | 110/220VAC |
Function & Indication
| Parameter | Value |
|---|---|
| Type | High/Low Level |
Mechanical
| Parameter | Value |
|---|---|
| Mounting type | DIN Rail |
| Termination style | Screw Terminal |
Environmental
| Parameter | Value |
|---|---|
| Operating temperature range | -10°C~55°C |
Other specifications
| Parameter | Value |
|---|---|
| Weight | 1.4 lbs (635 g) |
| Features | Alarm High - Contact, Two Wire/Three Probe |
| Output signal | Relay (3) |
| Sensitivity | 0 ~ 1.1kOhm |
| Distance - control to sensor | 800m |
Product details
Frequently asked questions
Where can I buy the 61F-G3NR AC110/220?
This part is sourced and quoted to order against an RFQ through independent distribution channels. Submit a request for current availability and pricing.
What is the supply voltage for this level controller?
The 61F-G3NR AC110/220 accepts 110/220VAC, covering both common line voltages without a tap change.
What is the maximum distance between controller and sensor probes?
The control-to-sensor distance is rated up to 800 m, allowing the controller to be panel-mounted far from the tank.
MPN
61F-G3NR AC110/220