Skip to main content
Omron 61F-G3T AC110/220 — General Purpose Relays

Omron 61F-G3T AC110/220 High/Low Level Controller, 110/220VA

MPN61F-G3T AC110/220
Active

Omron 61F series, High/Low Level controller, 61F-G3T AC110/220, 110/220VAC supply, SPDT (2 Form C) relay outputs, 0-5kOhm sensitivity, 600m max sensor distance, chassis mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-G3T AC110/220 — Identification
ParameterValue
Series61F
61F-G3T AC110/220 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage5A @ 220VAC
61F-G3T AC110/220 — Coil & Supply
ParameterValue
Supply voltage range110/220VAC
61F-G3T AC110/220 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-G3T AC110/220 — Mechanical
ParameterValue
Mounting typeChassis Mount
Termination styleScrew Terminal
61F-G3T AC110/220 — Environmental
ParameterValue
Operating temperature range-10°C~55°C
61F-G3T AC110/220 — Other specifications
ParameterValue
Weight2.1 lbs (952.5 g)
FeaturesAlarm High/Low - Contact
Output signalRelay (3)
Sensitivity0 ~ 5kOhm
Distance - control to sensor600m

Product details

The Omron 61F-G3T AC110/220 is a High/Low Level conductive level controller from the 61F series. It runs on a dual-rated 110/220VAC supply, making it a straight swap into panels wired for either voltage without a transformer tap change. Three relay outputs give you SPDT (2 Form C) contacts rated at 5A at 220VAC, enough to drive pump contactors or alarm indicators directly. Sensitivity is adjustable from 0 to 5 kOhm, which covers most conductive liquids — water, weak acids, coolants — but won't trigger on high-resistance fluids like deionized water or hydrocarbons. The control-to-sensor distance maxes out at 600 m, so the controller can sit in a central panel while the probes are out at the tank farm.

Chassis-mount form factor with screw terminals. Mount the unit on a backplate or inside a junction box — no DIN rail adapter included, so plan for screw-down lugs or a separate DIN-rail mounting bracket if that's your panel standard. If the enclosure sees radiant heat, keep the controller shaded or move it to a cooler location.

For BOM planning: this is a fast mover in plants with conductive-level tank control. Keep one on the shelf as a critical spare — a failed level controller on a sump or process tank can idle a line.

Frequently asked questions

What is the supply voltage for the 61F-G3T AC110/220?

The supply is dual-rated 110/220VAC. It accepts either voltage without a jumper change.

What is the sensitivity range of the 61F-G3T AC110/220?

Sensitivity is adjustable from 0 to 5 kOhm, covering most conductive liquids like water and coolants.

What is the maximum distance between the controller and the sensor probes?

The maximum control-to-sensor distance is 600 meters, allowing the controller to be panel-mounted away from the tank.

Where can I buy the 61F-G3T AC110/220?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
61F-G3T AC110/220