Skip to main content
Omron 61F-G4NL AC110/220 4KM — Process / Temperature Controllers

Omron 61F-G4NL AC110/220 4KM Level Controller, 4km Range

MPN61F-G4NL AC110/220 4KM
Active

Omron 61F-G4NL AC110/220 4KM, High/Low Level Controller, 61F Series, 110/220VAC supply, 4km max sensor distance, SPDT relay outputs, DIN-rail mount.

$677.66 – $697.70Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-G4NL AC110/220 4KM — Identification
ParameterValue
Series61F
TypeHigh/Low Level
61F-G4NL AC110/220 4KM — Electrical
ParameterValue
Supply voltage110/220VAC
61F-G4NL AC110/220 4KM — I/O
ParameterValue
Output typeRelay (6)
61F-G4NL AC110/220 4KM — Performance
ParameterValue
FeaturesIdling Prevention, Level Indication
61F-G4NL AC110/220 4KM — Environmental
ParameterValue
Operating temperature-10°C ~ 55°C
61F-G4NL AC110/220 4KM — Mechanical
ParameterValue
Mounting typeDIN Rail
Termination styleScrew Terminal
61F-G4NL AC110/220 4KM — Other specifications
ParameterValue
Weight1.9 lbs (861.8 g)
Sensitivity0 ~ 0.7kOhm
Contact formSPDT (2 Form C), SPDT (3 Form C)
Contact rating @ voltage3A @ 200VAC
Distance - control to sensor4km

Product details

Level Controller for Remote Tank Monitoring

The Omron 61F-G4NL AC110/220 4KM is a high/low level controller designed for conductive liquid detection in the 61F series. Its standout spec is the 4 km maximum distance between the controller and the remote sensor probe, making it suited for widely spaced tank farms or elevated reservoirs where running long cable runs is the norm. The dual-voltage supply (110/220 VAC) simplifies panel wiring across sites with different line voltages — one part number covers both.

The Type High/Low Level means the controller energizes or de-energizes the relay outputs based on whether the liquid level is above (high) or below (low) the probe setpoint — standard for fill/empty control in sumps, tanks, or cooling towers. The sensitivity range of 0 to 0.7 kOhm sets the threshold at which the controller detects liquid conductivity; adjust it to match the specific water or process fluid resistivity on site. The 3 A @ 200 VAC contact rating on the SPDT relays is sufficient for pilot-duty solenoid valves or alarm indicators, but for direct motor switching you will want an interposing contactor.

Screw terminals accept up to 2.5 mm² wire — strip 8 mm, torque to 0.5 Nm. The six relay outputs (2 Form C + 3 Form C) occupy the terminal rows; label each output clearly during commissioning to avoid confusion between the high-level and low-level circuits.

Frequently asked questions

Where can I buy the 61F-G4NL AC110/220 4KM and get a price?

We source this part to order against an RFQ. Submit a request and we will confirm current availability and pricing at quote time.

What does the 4 km sensor distance mean in practice?

The 4 km maximum distance between the controller and the sensor probe means you can locate the controller in a central panel while the probe sits at a remote tank or reservoir up to 4 km away, using standard 2-core cable for the connection.

What is the sensitivity range used for?

The 0 to 0.7 kOhm sensitivity adjustment sets the conductivity threshold at which the controller detects liquid. For clean water use a lower setting; for high-purity or non-conductive fluids the probe may not trigger at all — verify fluid conductivity before commissioning.

MPN
61F-G4NL AC110/220 4KM