Omron 61F-G4NR AC110/220 — General Purpose Relays

Omron 61F-G4NR AC110/220 Level Controller, 110/220VAC, DIN R

MPN61F-G4NR AC110/220
Active

Omron 61F series, High/Low Level controller, 110/220VAC, DIN Rail, SPDT relay outputs, 0~1.1kOhm sensitivity, 800m max sensor distance.

$677.66 – $697.70Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

61F-G4NR AC110/220 — Identification
ParameterValue
Series61F
61F-G4NR AC110/220 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C), SPDT (3 Form C)
Contact rating at voltage3A @ 200VAC
61F-G4NR AC110/220 — Coil & Supply
ParameterValue
Supply voltage range110/220VAC
61F-G4NR AC110/220 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-G4NR AC110/220 — Mechanical
ParameterValue
Mounting typeDIN Rail
Termination styleScrew Terminal
61F-G4NR AC110/220 — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-G4NR AC110/220 — Other specifications
ParameterValue
Weight1.9 lbs (861.8 g)
FeaturesIdling Prevention, Level Indication, Two Wire/Three Probe
Output signalRelay (6)
Sensitivity0 ~ 1.1kOhm
Distance - control to sensor800m

Product details

The Omron 61F-G4NR AC110/220 is a High/Low Level controller from the 61F series, designed to monitor and control liquid levels using conductive probes. It accepts a dual-range supply of 110/220VAC, making it straightforward to wire into existing panel voltage without a separate transformer. Sensitivity is adjustable from 0 to 1.1 kOhm, which covers most conductive liquids — water, weak acids, coolants — and the relay output (six relays total, configured as SPDT 2 Form C and 3 Form C) switches up to 3A at 200VAC. That contact rating is enough to drive a small pump contactor or alarm annunciator directly. The distance from controller to sensor can run up to 800 meters, which covers long tank runs in a plant.

The 0~1.1 kOhm sensitivity range means the unit detects liquid presence based on the resistance between probes. For clean water (typically 1–10 kOhm), you set the threshold near the low end; for more conductive fluids like brine or coolant, you adjust upward. This is the parameter that decides whether the controller triggers on foam, residue, or actual liquid — so dial it in during commissioning. The 800-meter maximum distance between controller and sensor is a practical spec for large tanks or remote sumps. It means the sensing head can be placed far from the panel without signal degradation, as long as the probe wiring stays within that loop resistance.

This class of level controller is common in water treatment, chemical dosing, coolant sump monitoring, and packaging machinery where a tank needs high/low level alarms or pump control. The idling prevention feature (listed in the specs) automatically stops the pump if the liquid level drops below the low probe, protecting the pump from running dry.

Frequently asked questions

What is the supply voltage for 61F-G4NR AC110/220?

It accepts 110/220VAC, dual-range, so it works on either nominal line voltage without a tap change.

What type of level control does this unit provide?

It is a High/Low Level controller, meaning it monitors two probe points for fill and drain logic.

How is 61F-G4NR AC110/220 mounted and terminated?

It mounts on a standard DIN rail and uses screw terminals for all connections.

What is the maximum distance between the controller and the sensor probes?

Up to 800 meters, which covers long cable runs in large facilities.

Where can I buy 61F-G4NR AC110/220 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.