Skip to main content
Omron 61F-GL AC100/200 2KM — General Purpose Relays

Omron 61F-GL AC100/200 2KM Level Controller, 5A SPDT, 2km

MPN61F-GL AC100/200 2KM
Active

Omron 61F series, High/Low Level controller, 61F-GL AC100/200 2KM, SPDT relay output, 100/200VAC supply, 2km max distance, chassis mount.

$276.79 – $285.38Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

61F-GL AC100/200 2KM — Identification
ParameterValue
Series61F
61F-GL AC100/200 2KM — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage5A @ 220VAC
61F-GL AC100/200 2KM — Coil & Supply
ParameterValue
Supply voltage range100/200VAC
61F-GL AC100/200 2KM — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-GL AC100/200 2KM — Mechanical
ParameterValue
Mounting typeChassis Mount
Termination styleScrew Terminal
61F-GL AC100/200 2KM — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-GL AC100/200 2KM — Other specifications
ParameterValue
Weight0.838 lb (380.11 g)
Output signalRelay
Sensitivity0 ~ 1.8kOhm
Distance - control to sensor2km

Product details

The Omron 61F-GL AC100/200 2KM is a conductive level controller that detects high or low liquid levels using probes. It's built for bulk tanks, sumps, or any wet well where you need a relay to kick a pump or valve when the level hits a set point. It runs on 100/200VAC supply and outputs through a SPDT relay (2 Form C) rated 5A at 220VAC — enough to directly switch a small pump contactor without an interposing relay. Sensitivity is adjustable from 0 to 1.8 kOhm, which means it works with plain stainless rods in clean water or slightly conductive process fluids. The 2 km max distance between controller and sensor head gives you flexibility to mount the electronics away from the tank.

Mounting and wiring in the field

Chassis mount with screw terminals — no DIN rail, so you'll need to drill the panel or use a separate DIN adapter plate if your enclosure is set up for rail. The screw terminals accept standard ring or fork lugs; strip length around 8 mm. If this lives in an unheated pump house in a northern winter, keep it above freezing.

The 5A @ 220VAC contact rating is resistive — if you're switching an inductive motor load, derate or add a contactor. The SPDT (2 Form C) gives one N.O. and one N.C. set of contacts, so you can wire both high-level alarm and low-level pump start from the same unit. Sensitivity range of 0 to 1.8 kOhm covers the conductivity of most water-based liquids. For oils or non-conductive fluids, you'd need a different sensing method (capacitive or ultrasonic).

Frequently asked questions

What is the max distance between the controller and the sensor?

The 61F-GL AC100/200 2KM supports a maximum distance of 2 km between the controller and the sensor electrodes.

What type of level control is this (high/low)?

It is a High/Low Level controller, meaning it can be wired for either fill-to-high or drain-to-low operation using the SPDT relay contacts.

MPN
61F-GL AC100/200 2KM