Specifications

61F-GN AC110/220 — Identification
ParameterValue
Series61F
61F-GN AC110/220 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 200VAC
61F-GN AC110/220 — Coil & Supply
ParameterValue
Supply voltage range110/220VAC
61F-GN AC110/220 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-GN AC110/220 — Mechanical
ParameterValue
Mounting typeDIN Rail
Termination styleScrew Terminal
61F-GN AC110/220 — Environmental
ParameterValue
Operating temperature range-10°C~55°C
61F-GN AC110/220 — Other specifications
ParameterValue
Weight0.694 lb (314.79 g)
Output signalRelay
Sensitivity0 ~ 4kOhm
Distance - control to sensor1km

Product details

The Omron 61F-GN AC110/220 is a conductive-type level controller from the 61F series, designed for high/low level detection in tanks, reservoirs, and process vessels. It operates on a dual-voltage supply of 110/220VAC and switches a relay output based on the resistance between its probe electrodes.

The 0 ~ 4kOhm sensitivity range means the controller triggers the relay when the resistance between the common and level probes drops below the set threshold — typical for water-based conductive liquids (tap water, coolant, wastewater). For liquids with lower conductivity (deionized water, some oils), the 4kOhm upper limit may not detect reliably; a lower-sensitivity model would be needed. The SPDT (2 Form C) contact arrangement provides one normally-open and one normally-closed set of changeover contacts per pole, rated 3A at 200VAC. That's enough to drive a small pump contactor coil or a pilot light directly, but not a motor load — the relay contacts are for signal-level switching, not power. The 1 km maximum distance between the controller and the sensor head means the probe wiring can run across a large plant floor or between buildings without signal degradation, as long as the cable resistance stays within the 4kOhm sensitivity window.

Frequently asked questions

Where can I buy 61F-GN AC110/220 and get a price?

The 61F-GN AC110/220 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What does the 0 ~ 4kOhm sensitivity mean for my liquid?

The sensitivity range means the controller detects liquid level when the resistance between the probe and common electrode falls between 0 and 4,000 ohms. This works for most conductive liquids like water, coolants, and dilute acids. For low-conductivity liquids (deionized water, hydrocarbons), the resistance may exceed 4kOhm and the controller will not trigger.

What is the maximum distance between the controller and the sensor?

The maximum distance from the controller to the sensor probe is 1 km, provided the total loop resistance stays within the 4kOhm sensitivity range.