Skip to main content
Omron 61F-GP-N AC220 — General Purpose Relays

Omron 61F-GP-N AC220 Level Controller, 220VAC SPDT, 3A

MPN61F-GP-N AC220
Obsolete

Omron 61F series, High/Low Level controller, 220VAC, SPDT (2 Form C) relay output, 3A @ 250VAC, socketable 11-pin octal base.

$319.74 – $701.07Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

61F-GP-N AC220 — Identification
ParameterValue
Series61F
61F-GP-N AC220 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 250VAC
61F-GP-N AC220 — Coil & Supply
ParameterValue
Supply voltage range220VAC
61F-GP-N AC220 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-GP-N AC220 — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 11 Pin (Octal)
61F-GP-N AC220 — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-GP-N AC220 — Other specifications
ParameterValue
Weight0.342 lb (155.13 g)
FeaturesLevel Indication
Output signalRelay
Sensitivity0 ~ 4kOhm
Distance - control to sensor1km

Product details

The Omron 61F-GP-N AC220 is a conductive-type level controller from the 61F series, designed for high/low level detection in tanks, sumps, and reservoirs. It operates on a 220VAC supply and uses a relay output (SPDT, 2 Form C) rated at 3A @ 250VAC to switch pumps, valves, or alarms. Sensitivity is adjustable from 0 to 4kOhm, which lets you tune the detection threshold for different liquid conductivities — from clean water to more conductive process fluids. The control-to-sensor distance can run up to 1 km, making this suitable for remote tank farms or deep wells where the controller sits in a panel far from the probes. It mounts on an 11-pin octal socket (sold separately), so replacement is a plug-in swap — no rewiring at the terminal block.

Frequently asked questions

What is the 61F-GP-N AC220's sensitivity range?

The sensitivity is adjustable from 0 to 4kOhm, allowing you to set the detection threshold for different liquid conductivities.

What is the maximum distance between the controller and the sensor probes?

The control-to-sensor distance can be up to 1 km, making it suitable for remote tank farms or deep wells.

MPN