Skip to main content
Omron 61F-GP-N8-V50 AC110 — General Purpose Relays

Omron 61F-GP-N8-V50 AC110 Level Controller, 110VAC, Adjustab

MPN61F-GP-N8-V50 AC110
Active

Omron 61F Series, High/Low Level Controller, SPDT (2 Form C) Relay Output, 110VAC Supply, Socketable, Plug In 8-Pin Octal, Adjustable Sensitivity 0 ~ 50kOhm.

$263.31 – $674.90Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

61F-GP-N8-V50 AC110 — Identification
ParameterValue
Series61F
61F-GP-N8-V50 AC110 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 250VAC
61F-GP-N8-V50 AC110 — Coil & Supply
ParameterValue
Supply voltage range110VAC
61F-GP-N8-V50 AC110 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-GP-N8-V50 AC110 — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 8 Pin (Octal)
61F-GP-N8-V50 AC110 — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-GP-N8-V50 AC110 — Other specifications
ParameterValue
Weight0.342 lb (155.13 g)
FeaturesAdjustable Sensitivity
Output signalRelay
Sensitivity0 ~ 50kOhm
Distance - control to sensor50m

Product details

The Omron 61F-GP-N8-V50 AC110 is a High/Low level controller from the 61F series, designed for conductive liquid level detection in tanks, reservoirs, and process vessels. It operates on a 110VAC supply and provides SPDT relay output (2 Form C) rated at 3A @ 250VAC — enough to drive a small pump contactor or alarm directly. The adjustable sensitivity range of 0 to 50 kΩ lets you tune it for different liquid conductivities, from clean water to mildly conductive process fluids. Socketable via an 8-pin octal base. The controller can sit up to 50 meters from the sensing electrodes.

Sensitivity and Application Fit

The 0 to 50 kΩ sensitivity adjustment sets the threshold resistance between the probe and common. The High/Low type means it has two setpoints: one for high-level (pump off or alarm) and one for low-level (pump on or refill). The relay contacts switch accordingly, making it a direct replacement for float-switch logic in many tank-level applications.

Frequently asked questions

What is the adjustable sensitivity range on this level controller?

The sensitivity is adjustable from 0 to 50 kΩ, which sets the resistance threshold between the probe and common for detecting liquid presence. This covers most conductive liquids from tap water to mild chemicals.

What voltage does the 61F-GP-N8-V50 AC110 require?

It runs on 110VAC supply. The relay output is rated at 3A @ 250VAC for switching external loads.

How far can the sensor be from the controller?

The maximum distance between the controller and the sensing electrodes is 50 meters. This allows the controller to be mounted in a panel while the probes are at the tank.

MPN
61F-GP-N8-V50 AC110