Skip to main content
Omron 61F-GP-N8HY 110VAC — General Purpose Relays

Omron 61F-GP-N8HY 110VAC Level Controller, Obsolete

MPN61F-GP-N8HY 110VAC
Active

Omron 61F series, High/Low Level Controller, 61F-GP-N8HY 110VAC, relay output, SPDT (2 Form C), 110VAC supply, socketable, plug-in 8-pin octal termination.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

61F-GP-N8HY 110VAC — Identification
ParameterValue
Series61F
61F-GP-N8HY 110VAC — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 250VAC
61F-GP-N8HY 110VAC — Coil & Supply
ParameterValue
Supply voltage range110VAC
61F-GP-N8HY 110VAC — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-GP-N8HY 110VAC — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 8 Pin (Octal)
61F-GP-N8HY 110VAC — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-GP-N8HY 110VAC — Other specifications
ParameterValue
Weight0.342 lb (155.13 g)
Output signalRelay
Sensitivity15kOhm ~ 70kOhm
Distance - control to sensor50m

Product details

The Omron 61F-GP-N8HY 110VAC is a High/Low Level controller from the 61F series, designed for conductive liquid level detection in tanks, reservoirs, and process vessels. It operates on a 110VAC supply and provides a relay output with SPDT (2 Form C) contacts rated at 3A @ 250VAC. The sensitivity range of 15kΩ to 70kΩ allows adjustment for different liquid conductivities, and the unit can sense up to 50m from the electrode. Termination is via an 8-pin octal plug-in base, making it socket-mountable for quick replacement in a panel.

The 15kΩ–70kΩ sensitivity range means this controller can be tuned to detect liquids with varying conductivity — from relatively pure water (higher resistance) to conductive process fluids (lower resistance). The High/Low Level function provides two set points: a high-level alarm or pump-stop and a low-level refill or alarm, using a single electrode pair or three-electrode probe. The 50m maximum distance between controller and sensor allows the electronics to be mounted remotely from the tank, which is useful in hazardous or space-constrained areas. The 110VAC supply and octal base are standard for panel-mount level controls in this class, so replacement in an existing socket is straightforward — but verify the wiring scheme against the original unit, as pin assignments may differ between manufacturers.

Deployment Context

This controller is typically deployed in water and wastewater treatment, chemical dosing, and industrial process tanks where conductive liquid level detection is acceptable. The socketable, plug-in design suits DIN-rail or panel-mount enclosures where quick replacement without rewiring is a maintenance requirement.

Frequently asked questions

Where can I buy 61F-GP-N8HY 110VAC?

This obsolete part is sourced through independent distribution channels. It is quoted to order against an RFQ; availability and current pricing are confirmed at the time of quote.

What is the sensitivity range of 61F-GP-N8HY 110VAC?

The sensitivity is adjustable from 15kΩ to 70kΩ, allowing the controller to be tuned for different liquid conductivities.

What is the maximum distance between the controller and the sensor?

The maximum control distance to the sensor (electrode) is 50 meters.

What type of output does 61F-GP-N8HY 110VAC provide?

It provides a relay output with SPDT (2 Form C) contacts rated at 3A @ 250VAC.

MPN