Omron 61F-GP-N8Y 110VAC — General Purpose Relays

Omron 61F-GP-N8Y 110VAC Level Controller, High/Low, Obsolete

MPN61F-GP-N8Y 110VAC
Active

Omron 61F series, High/Low Level Controller, relay output, SPDT (2 Form C), 110VAC supply, plug-in 8-pin octal base, sensitivity 0~4kOhm, max sensor distance 1km.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

61F-GP-N8Y 110VAC — Identification
ParameterValue
Series61F
61F-GP-N8Y 110VAC — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 250VAC
61F-GP-N8Y 110VAC — Coil & Supply
ParameterValue
Supply voltage range110VAC
61F-GP-N8Y 110VAC — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-GP-N8Y 110VAC — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 8 Pin (Octal)
61F-GP-N8Y 110VAC — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-GP-N8Y 110VAC — Other specifications
ParameterValue
Weight0.342 lb (155.13 g)
Output signalRelay
Sensitivity0 ~ 4kOhm
Distance - control to sensor1km

Product details

The Omron 61F-GP-N8Y 110VAC is a High/Low Level conductive level controller from the 61F series, with a relay output and SPDT (2 Form C) contact arrangement rated at 3A @ 250VAC. It operates on a 110VAC supply and terminates via a standard 8-pin octal plug-in base. The sensitivity range of 0 to 4kOhm allows it to detect liquid conductivity in various media, and the maximum distance from controller to sensor is 1km — suitable for remote tank monitoring where the control panel sits centrally and the probes are at the vessel.

The 0~4kOhm sensitivity range governs the probe selection: a higher-resistance liquid (e.g., deionized water or certain process fluids) may require a more sensitive setting, while conductive solutions like brine or wastewater will trigger reliably across the band. The 1km maximum control-to-sensor distance is a cable-length limit — beyond that, voltage drop and stray capacitance can cause false triggering or failure to detect. The SPDT (2 Form C) relay output gives one normally-open and one normally-closed contact per pole, allowing fail-safe wiring for high- or low-level alarm logic. The 3A @ 250VAC contact rating is adequate for pilot-duty control of contactors or alarm annunciators, but not for direct motor switching.

Integration Notes

Socketable mounting via an 8-pin octal base means the controller plugs into a standard relay socket — no hardwiring to the unit itself, which simplifies replacement during line-down maintenance. Termination style is plug-in, 8-pin (octal), so verify the base pinout matches the existing wiring before committing the BOM line.

Frequently asked questions

What is the closest pin-compatible alternative to 61F-GP-N8Y 110VAC?

No official successor or pin-compatible replacement is listed in the manufacturer's lifecycle record. A cross-reference would require verifying the socket base (8-pin octal), supply voltage (110VAC), sensitivity range (0~4kOhm), and output configuration (SPDT relay) against a current Omron 61F-series variant — this must be confirmed against the specific application requirements.

Where can I buy the 61F-GP-N8Y 110VAC?

This obsolete part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or lead-time figure can be stated here.

What compliance documentation does Omron provide for 61F-GP-N8Y 110VAC?

The evidence does not list specific compliance documentation (RoHS, REACH, UL, IEC) for this part. Given its Obsolete status, original declarations may be limited; verify documentation requirements with the supplier at the time of RFQ.

MPN