Specifications

61F-GP-NH AC100 — Identification
ParameterValue
Series61F
61F-GP-NH AC100 — Contacts & Switching
ParameterValue
Contact formSPDT (2 Form C)
Contact rating at voltage3A @ 250VAC
61F-GP-NH AC100 — Coil & Supply
ParameterValue
Supply voltage range100VAC
61F-GP-NH AC100 — Function & Indication
ParameterValue
TypeHigh/Low Level
61F-GP-NH AC100 — Mechanical
ParameterValue
Mounting typeSocketable
Termination stylePlug In, 11 Pin (Octal)
61F-GP-NH AC100 — Environmental
ParameterValue
Operating temperature range-10°C ~ 55°C
61F-GP-NH AC100 — Other specifications
ParameterValue
Weight0.342 lb (155.13 g)
Output signalRelay
Sensitivity10kOhm ~ 40kOhm
Distance - control to sensor50m

Product details

The Omron 61F-GP-NH AC100 is a conductive-type level controller from the 61F series, wired for high/low level detection in tanks or sumps. It operates on a 100VAC supply and uses the conductivity of the liquid between two or three probe electrodes to sense the level — no floats, no moving parts in the tank. The relay output (SPDT, 2 Form C, rated 3A @ 250VAC) switches a pump or valve based on the fill/drain logic selected by the wiring configuration between the common and high/low terminals. Sensitivity is adjustable across 10kOhm ~ 40kOhm, which means it can be tuned for different liquid conductivities — from relatively conductive tap water (lower resistance) up to less conductive fluids like distilled water or some chemical solutions (higher resistance). The sensor-to-controller distance can run up to 50m, so the controller can be panel-mounted well away from the vessel. It mounts on an 11-pin octal socket, making it quick to swap for maintenance or replacement.

Frequently asked questions

Where can I buy 61F-GP-NH AC100?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the sensitivity range on 61F-GP-NH AC100?

The sensitivity is adjustable from 10kOhm to 40kOhm, allowing the controller to be tuned for different liquid conductivities.

What is the maximum distance between the controller and the sensor probes?

The maximum distance from the 61F-GP-NH AC100 controller to the sensor electrodes is 50m.

What type of output does 61F-GP-NH AC100 have?

It has a relay output with SPDT (2 Form C) contacts rated at 3A @ 250VAC.

MPN